Failure of the Override Switch 3


TASK 27-40-00-810-806-A
Failure of the Override Switch 3


1. Possible Causes
  • SEC-2 [1CE2]
  • wiring from the DSI-24 signal of the SEC 2 (1CE2) to the first terminal block
  • wiring from the overriding signal of the THS actuator (9CE) to the first terminal block
  • pitch trim actuator
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-44-57-000-001
Removal of the Pitch Trim Actuator from the THS Actuator
AMM 27-44-57-400-001
Installation of the Pitch Trim Actuator to the THS Actuator
ASM 279413
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-40-00-700-060-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-40-00-810-055-A
A. If the BITE test gives the maintenance message:
THS ACTR OVRD SW3 9CE
   (1) If the fault continues:
  • do a check of the wiring from the DSI-24 signal of the SEC 2 (1CE2) to the first terminal block COM part and MON part ASM 279413.
     (a) If there is no continuity, repair the wiring.
     (b) If there is continuity:
  • do a check of the wiring from the overriding signal of the THS actuator (9CE) to the first terminal block, ASM 279413.
       1 If there is no continuity, repair the wiring.
       2 If there is continuity:
Subtask 27-40-00-700-061-A
B. Do the tests given in Para. 3.