W DOC AIRBUS | TSM A320F

Failure of the Override Switch 1


TASK 27-40-00-810-802-A
Failure of the Override Switch 1


1. Possible Causes
  • ELAC-2 [2CE2]
  • wiring from the DSI-31 signal of the ELAC 2 (2CE2) to the first terminal block
  • wiring from the overriding signal of the THS actuator (9CE) to the first terminal block
  • pitch trim actuator
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-44-57-000-001
Removal of the Pitch Trim Actuator from the THS Actuator
AMM 27-44-57-400-001
Installation of the Pitch Trim Actuator to the THS Actuator
ASM 279313
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-40-00-700-052-A
A. Test
   (1) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-40-00-810-051-A
A. If the BITE test gives the maintenance message:
THS ACTR OVRD SW1 9CE
   (1) If the fault continues:
  • do a check of the wiring from the DSI-31 signal of the ELAC 2 (2CE2) to the first terminal block, COM part and MON part ASM 279313.
     (a) If there is no continuity, repair the wiring.
     (b) If there is continuity:
  • do a check of the wiring from the overriding signal of the THS actuator (9CE) to the first terminal block ASM 279313.
       1 If there is no continuity, repair the wiring.
       2 If there is continuity:
Subtask 27-40-00-700-053-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:35 UTC