Failure of the Override Switch 1
TASK 27-40-00-810-802-A
Failure of the Override Switch 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-40-00-700-052-A 4. Fault Isolation
Subtask 27-40-00-810-051-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:35 UTC
Failure of the Override Switch 1
1. Possible Causes
- ELAC-2 [2CE2]
wiring from the DSI-31 signal of the ELAC 2 (2CE2) to the first terminal block wiring from the overriding signal of the THS actuator (9CE) to the first terminal block - pitch trim actuator
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-44-57-000-001 | Removal of the Pitch Trim Actuator from the THS Actuator |
| AMM 27-44-57-400-001 | Installation of the Pitch Trim Actuator to the THS Actuator |
| ASM 279313 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-40-00-700-052-A 4. Fault Isolation
Subtask 27-40-00-810-051-A
A. If the BITE test gives the maintenance message:
THS ACTR OVRD SW1 9CE
(b) If there is continuity:
2 If there is continuity:
Subtask 27-40-00-700-053-A THS ACTR OVRD SW1 9CE
- replace the ELAC-2 [2CE2] AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- do a check of the
wiring from the DSI-31 signal of the ELAC 2 (2CE2) to the first terminal block , COM part and MON part ASM 279313.
(b) If there is continuity:
- do a check of the
wiring from the overriding signal of the THS actuator (9CE) to the first terminal block ASM 279313.
2 If there is continuity:
- replace the pitch trim actuator AMM 27-44-57-000-001 and AMM 27-44-57-400-001.
B. Do the tests given in Para. 3.