Failure of the THS Actuator Servo Motor 3 for the SEC 2
TASK 27-40-00-810-801-A
Failure of the THS Actuator Servo Motor 3 for the SEC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-40-00-700-050-A
Subtask 27-40-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:35 UTC
Failure of the THS Actuator Servo Motor 3 for the SEC 2
1. Possible Causes
- SEC-2 [1CE2]
- RELAY-PITCH TRIM ACTUATOR MOTOR 3 SPLY [36CE3]
- electronic module 3
wiring of the enable signal from the THS actuator (9CE) to the SEC 2 (1CE2) wiring of the DSI-25 signal from the SEC 2 (1CE2) to the THS actuator (9CE) wiring from the relay (36CE3) to the SEC 2 (1CE2) and to the THS actuator (9CE)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-41-00-861-002 | Energize the Aircraft Electrical Circuits from the External Power |
| AMM 27-44-57-000-002 | Removal of the Electronic Modules of the Pitch Trim Actuator |
| AMM 27-44-57-400-002 | Installation of the Electronic Modules of the Pitch Trim Actuator |
| ASM 279413 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
| AMM 29-10-00-864-001 | Depressurize the Green Hydraulic System |
| AMM 29-10-00-864-002 | Depressurize the Yellow Hydraulic System |
| AMM 29-10-00-864-003 | Depressurize the Blue Hydraulic System |
Subtask 27-40-00-700-050-A
A. Test
(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Make sure that the Green, Blue and Yellow hydraulic systems are not pressurized AMM 29-10-00-864-001, AMM 29-10-00-864-003 and AMM 29-10-00-864-002.
(3) On the panel 24VU:
(5) On the panel 24VU:
4. Fault Isolation(1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
(2) Make sure that the Green, Blue and Yellow hydraulic systems are not pressurized AMM 29-10-00-864-001, AMM 29-10-00-864-003 and AMM 29-10-00-864-002.
(3) On the panel 24VU:
- release the FLT CTL/SEC2 pushbutton switch.(On this pushbutton switch, the OFF legend comes on).
(5) On the panel 24VU:
- push the FLT CTL/SEC2 pushbutton switch.(On this pushbutton switch, the OFF legend goes off).
NOTE: Wait 60 seconds before you start the BITE test.
Subtask 27-40-00-810-050-A
A. If the BITE test gives the maintenance message:
THS ACTR SERVO MOT 3 9CE OF SEC2
(b) If there is continuity:
2 If there is continuity:
Subtask 27-40-00-700-051-A THS ACTR SERVO MOT 3 9CE OF SEC2
- replace the SEC-2 [1CE2] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
- replace the RELAY-PITCH TRIM ACTUATOR MOTOR 3 SPLY [36CE3] (Ref. IPC 27920803).
- replace the electronic module 3 AMM 27-44-57-000-002 and AMM 27-44-57-400-002.
- do a check of the
wiring of the enable signal from the THS actuator (9CE) to the SEC 2 (1CE2) ASM 279413.
(b) If there is continuity:
- do a check of the
wiring of the DSI-25 signal from the SEC 2 (1CE2) to the THS actuator (9CE) ASM 279413.
2 If there is continuity:
- do a check and repair the
wiring from the relay (36CE3) to the SEC 2 (1CE2) and to the THS actuator (9CE) ASM 279413.
B. Do the tests given in Para. 3.