Airframe Vibration due to the Elevator
TASK 27-30-00-810-850-A
Airframe Vibration due to the Elevator
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-700-136-A
Subtask 27-30-00-810-097-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:35 UTC
Airframe Vibration due to the Elevator
1. Possible Causes
- elevator servo controls and hinge bearings
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 05-50-00-810-801-A | Identification of the Cause of In-Flight Airframe Vibrations and/or Noises |
| AMM 27-34-00-200-001 | Check of the Elevator Servo Controls and Hinge Bearings for Excessive Play and Condition |
| AMM 27-34-00-820-003 | Adjustment of the Elevator and Hydraulic Actuation with the Gauge-Elevator Neutral Setting (98D27309002000) |
| AMM 55-26-00-200-002 | Check of Elevator Attachment Fittings for Wear, LH/RH |
Subtask 27-30-00-700-136-A
A. Test
Make sure that the identification of the cause of the vibrations is correct (Ref. TSM TASK 05-50-00-810-801).
4. Fault IsolationMake sure that the identification of the cause of the vibrations is correct (Ref. TSM TASK 05-50-00-810-801).
Subtask 27-30-00-810-097-A
A. If you feel vibrations in the rear cabin:
(1) Do a check of the elevator servo controls and hinge bearings for too much play and condition AMM 27-34-00-200-001.
(2) Do a check of the adjustment of the elevator and hydraulic actuation AMM 27-34-00-820-003
(3) If the fault continues, do an inspection/check of the elevator attach fittings AMM 55-26-00-200-002.
(1) Do a check of the elevator servo controls and hinge bearings for too much play and condition AMM 27-34-00-200-001.
(2) Do a check of the adjustment of the elevator and hydraulic actuation AMM 27-34-00-820-003
(3) If the fault continues, do an inspection/check of the elevator attach fittings AMM 55-26-00-200-002.