Failure of the Right Elevator Position MON Transducer
TASK 27-30-00-810-836-A
Failure of the Right Elevator Position MON Transducer
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-700-130-A
Subtask 27-30-00-810-091-C
[Rev.8 from Aug 2018]
2026.04.04 04:27:33 UTC
Failure of the Right Elevator Position MON Transducer
1. Possible Causes
- XDCR UNIT-ELEV POS, R [49CE2]
- wiring of the POS RVDT MON SPLY signal
wiring of the POS RVDT MON V1, V2 signals
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-824-A | Loss of the ACS1 Signal of the ELAC2 MON Side and SEC2 MON Side |
| TSM TASK 31-32-00-810-933-A | Failure of the Analog Links |
| AMM 27-92-13-000-001 | Removal of the Elevator Position Transducer-Unit |
| AMM 27-92-13-400-001 | Installation of the Elevator Position Transducer-Unit |
| ASM 279307 | |
| ASM 279308 | |
| ASM 279407 | |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-30-00-700-130-A
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
(a) If the ground scanning gives the maintenance message:
R ELEV POS MON XDCR OF ELAC2/SEC2
L B ELEV MODE XDCR 34CE3
L ELEV POS MON XDCR OF ELAC2/SEC2
R B ELEV MODE XDCR 34CE4
R ELEV POS MON XDCR OF ELAC2/SEC2
ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE
SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
4. Fault Isolation(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
(a) If the ground scanning gives the maintenance message:
R ELEV POS MON XDCR OF ELAC2/SEC2
- refer to Para. Fault Isolation.
L B ELEV MODE XDCR 34CE3
L ELEV POS MON XDCR OF ELAC2/SEC2
R B ELEV MODE XDCR 34CE4
R ELEV POS MON XDCR OF ELAC2/SEC2
ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE
SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
- do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-824).
Subtask 27-30-00-810-091-C
A. If the test gives the maintenance message R ELEV POS MON XDCR OF ELAC2/SEC2:
(a) Do a check of the wiring of the POS RVDT MON SPLY signal from the transducer unit (49CE2) plug A to the first terminal block ASM 279308:
wiring of the POS RVDT MON V1, V2 signals from the transducer unit (49CE2) plug A to the first terminal block ASM 279308.
Subtask 27-30-00-700-131-A - disconnect and cross the electrical connectors of the elevator position transducer unit (49CE2) ASM 279308 and do the test given in Para. 3.
NOTE: After the test connect the electrical connectors on their initial plugs.
(1) If the fault continues: - do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-933) related to the ANI 2-X analog input signal of the ELAC COM and SEC COM ASM 279307 and ASM 279407.
- replace the XDCR UNIT-ELEV POS, R [49CE2] AMM 27-92-13-000-001 and AMM 27-92-13-400-001.
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
(3) If the test gives the maintenance message R ELEV POS MON XDCR OF ELAC2/SEC2: (a) Do a check of the wiring of the POS RVDT MON SPLY signal from the transducer unit (49CE2) plug A to the first terminal block ASM 279308:
- if there is continuity, see Para. (b)
- if there is no continuity, repair the above wiring.
B. Do the test given in Para. 3.