Failure of the Right Yellow Elevator-Servocontrol Position-Transducer
TASK 27-30-00-810-834-A
Failure of the Right Yellow Elevator-Servocontrol Position-Transducer
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-700-104-A
Subtask 27-30-00-810-077-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:33 UTC
Failure of the Right Yellow Elevator-Servocontrol Position-Transducer
1. Possible Causes
- SERVO CTL-R ELEVATOR, INBD Y [34CE2]
wiring of the POS RVDT COM SPLY signal from the servocontrol (34CE2) to the first terminal block wiring of the POS RVDT COM V1, V2 signals from the servocontrol (34CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 27-90-00-810-823-A | Loss of the ACS1 Signal of the ELAC2 COM Side and SEC2 COM Side |
| TSM TASK 31-32-00-810-933-A | Failure of the Analog Links |
| AMM 27-34-00-040-001 | Elevator Servocontrol Position-Transducer - Connection of the Spare Transducer |
| AMM 27-34-00-440-001 | Reactivation of Elevator Servocontrol Position-Transducer |
| AMM 27-34-51-000-001 | Removal of the Elevator Servo Control |
| AMM 27-34-51-400-001 | Installation of the Elevator Servo Control |
| ASM 279308 | |
| ASM 279408 | |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-30-00-700-104-A
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
(a) If the ground scanning gives the maintenance message:
R Y ELEV pos XDCR 34CE2 COM E2/S2:USE STBY XDCR
L G ELEV pos XDCR 34CE1 COM E2/S2:USE STBY XDCR
R Y ELEV pos XDCR 34CE2 COM E2/S2:USE STBY XDCR
ELAC2 COM OR INPUT OF THS ACTR XDCR1 9CE
SEC2 COM OR INPUT OF THS ACTR XDCR3 9CE
4. Fault Isolation(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
(a) If the ground scanning gives the maintenance message:
R Y ELEV pos XDCR 34CE2 COM E2/S2:USE STBY XDCR
- refer to Para. Fault Isolation.
L G ELEV pos XDCR 34CE1 COM E2/S2:USE STBY XDCR
R Y ELEV pos XDCR 34CE2 COM E2/S2:USE STBY XDCR
ELAC2 COM OR INPUT OF THS ACTR XDCR1 9CE
SEC2 COM OR INPUT OF THS ACTR XDCR3 9CE
- do this trouble shooting procedure (Ref. TSM TASK 27-90-00-810-823).
Subtask 27-30-00-810-077-A
A. If the test gives the maintenance message:
R Y ELEV POS XDCR 34CE2 COM E2/S2 : USE STBY XDCR
(1) Deactivate the defective RVDT and connect the spare RVDT AMM 27-34-00-040-001 and AMM 27-34-00-440-001.
(2) If the fault continues:
(a) Do a check of thewiring of the POS RVDT COM SPLY signal from the servocontrol (34CE2) to the first terminal block ASM 279308:
wiring of the POS RVDT COM V1, V2 signals from the servocontrol (34CE2) to the first terminal block ASM 279308.
Subtask 27-30-00-700-105-A R Y ELEV POS XDCR 34CE2 COM E2/S2 : USE STBY XDCR
(1) Deactivate the defective RVDT and connect the spare RVDT AMM 27-34-00-040-001 and AMM 27-34-00-440-001.
NOTE: These AMM tasks are only applicable if the servocontrol has a spare RVDT (RVDT triplex or RVDT duplex).
(a) If the servocontrol has no spare RVDT (RVDT simplex), continue the procedure to the subsequent step (4.A.(2)). (2) If the fault continues:
- do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-933) related to the ANI 2-2 analog input signal of the ELAC COM and SEC COM ASM 279308 and ASM 279408.
- replace the SERVO CTL-R ELEVATOR, INBD Y [34CE2] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
(4) If the fault continues: (a) Do a check of the
- if there is continuity, see Para. (b)
- if there is no continuity, repair the above wiring.
B. Do the tests given in Para. 3.