Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the SEC 1
TASK 27-30-00-810-830-A
Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the SEC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-700-096-A
Subtask 27-30-00-810-073-B
[Rev.8 from Aug 2018]
2026.04.04 04:27:32 UTC
Loss of the Signal of the Right Blue Elevator-Servocontrol Servovalve by the SEC 1
1. Possible Causes
- SEC-1 [1CE1]
- XDCR UNIT-ELEV POS, R [49CE2]
- servovalve of the servocontrol 34CE4
- SERVO CTL-R ELEVATOR, OUTBD B [34CE4]
wiring of the SV XDCR (LVDT) V1 signal from the servocontrol (34CE4) to the SEC 1 (1CE1) wiring of the SV XDCR (LVDT) SPLY signal from the servocontrol (34CE4) to the first terminal block wiring of the POS XDCR MON (RVDT) signal from the transducer unit (49CE2) to the SEC 1 (1CE1) wiring of the POS XDCR COM (RVDT) signal from the servocontrol (34CE4) to the SEC 1 (1CE1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-34-51-000-001 | Removal of the Elevator Servo Control |
| AMM 27-34-51-000-008 | Removal of the Elevator Servo Control Actuator Servo Valve |
| AMM 27-34-51-400-001 | Installation of the Elevator Servo Control |
| AMM 27-34-51-400-003 | Installation of the Elevator Servo Control Actuator Servo Valve |
| AMM 27-92-13-000-001 | Removal of the Elevator Position Transducer-Unit |
| AMM 27-92-13-400-001 | Installation of the Elevator Position Transducer-Unit |
| ASM 279407 | |
| AMM 27-94-34-000-001 | Removal of the SEC |
| AMM 27-94-34-400-001 | Installation of the SEC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-30-00-700-096-A
A. Test
(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
4. Fault Isolation(1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
NOTE: Before you start the operational test procedure, release the FLT CTL/ELAC 1, FLT CTL/ELAC 2 and FLT CTL/SEC 2 pushbutton switches (on these pushbutton switches, the OFF legends come on).
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001. Subtask 27-30-00-810-073-B
A. If the test gives the maintenance message:
SEC1 MON OR WIRING TO R B ELEV SERVO VLV 34CE4
(a) Replace the XDCR UNIT-ELEV POS, R [49CE2] AMM 27-92-13-000-001 and AMM 27-92-13-400-001.
(2) If the fault continues:
(a) Do a check of thewiring of the SV XDCR (LVDT) V1 signal from the servocontrol (34CE4) to the SEC 1 (1CE1) ASM 279407:
wiring of the SV XDCR (LVDT) SPLY signal from the servocontrol (34CE4) to the first terminal block ASM 279407.
wiring of the POS XDCR MON (RVDT) signal from the transducer unit (49CE2) to the SEC 1 (1CE1) ASM 279407.
wiring of the POS XDCR COM (RVDT) signal from the servocontrol (34CE4) to the SEC 1 (1CE1) ASM 279407.
Subtask 27-30-00-700-097-A SEC1 MON OR WIRING TO R B ELEV SERVO VLV 34CE4
- Replace the SEC-1 [1CE1] AMM 27-94-34-000-001 and AMM 27-94-34-400-001.
(a) Replace the XDCR UNIT-ELEV POS, R [49CE2] AMM 27-92-13-000-001 and AMM 27-92-13-400-001.
(2) If the fault continues:
- Replace the servovalve of the servocontrol 34CE4 AMM 27-34-51-000-008 and AMM 27-34-51-400-003.
- Replace the SERVO CTL-R ELEVATOR, OUTBD B [34CE4] AMM 27-34-51-000-001 and AMM 27-34-51-400-001.
(a) Do a check of the
- If there is continuity, see Para. (b)
- If there is no continuity, repair the above wiring.
- If there is continuity, see Para. (c)
- If there is no continuity, repair the above wiring.
- If there is continuity, see Para. (d)
- If there is no continuity, repair the above wiring.
B. Do the tests given in Para. 3.