Loss of the Right Elevator because of its two Servocontrols
TASK 27-30-00-810-826-A
Loss of the Right Elevator because of its two Servocontrols
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-30-00-700-129-A
Subtask 27-30-00-810-090-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:32 UTC
Loss of the Right Elevator because of its two Servocontrols
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-34-00-200-001 | Check of the Elevator Servo Controls and Hinge Bearings for Excessive Play and Condition |
| AMM 27-34-00-710-001 | Operational Test of the Elevator and Hydraulic Actuation |
| AMM 27-34-51-000-001 | Removal of the Elevator Servo Control |
| AMM 27-34-51-400-001 | Installation of the Elevator Servo Control |
| AMM 27-96-00-710-008 | Operational Test of the Damping Measurement (Elevator) |
Subtask 27-30-00-700-129-A
A. Test
(1) Not applicable, you cannot confirm this fault on the ground.
4. Fault Isolation(1) Not applicable, you cannot confirm this fault on the ground.
Subtask 27-30-00-810-090-A
A. Do a check of the right elevator servocontrols and hinge bearings for too much play and condition AMM 27-34-00-200-001.
(1) Do an operational test of the damping measurement (Elevator) AMM 27-96-00-710-008:
(1) Do an operational test of the damping measurement (Elevator) AMM 27-96-00-710-008:
- if the result of the test is not in the tolerances, see Para. (a)
- if the result of the test is in the tolerances, see Para. (b).
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
(b) Do the operational test of the elevator and hydraulic actuation AMM 27-34-00-710-001.