W DOC AIRBUS | TSM A320F

Loss of the Signal of the Left Green Elevator-Servocontrol Servovalve by the SEC 2


TASK 27-30-00-810-819-A
Loss of the Signal of the Left Green Elevator-Servocontrol Servovalve by the SEC 2


1. Possible Causes
  • SEC-2 [1CE2]
  • XDCR UNIT-ELEV POS, L [49CE1]
  • servovalve of the servocontrol 34CE1
  • SERVO CTL-L ELEVATOR, INBD G [34CE1]
  • wiring of the SV XDCR (LVDT) V1 signal from the servocontrol (34CE1) to the SEC 2 (1CE2)
  • wiring of the SV XDCR (LVDT) SPLY signal from the servocontrol (34CE1) to the first terminal block
  • wiring of the POS XDCR MON (RVDT) signal from the transducer unit (49CE1) to the SEC 2 (1CE2)
  • wiring of the POS XDCR COM (RVDT) signal from the servocontrol (34CE1) to the SEC 2 (1CE2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-34-51-000-001
Removal of the Elevator Servo Control
AMM 27-34-51-000-008
Removal of the Elevator Servo Control Actuator Servo Valve
AMM 27-34-51-400-001
Installation of the Elevator Servo Control
AMM 27-34-51-400-003
Installation of the Elevator Servo Control Actuator Servo Valve
AMM 27-92-13-000-001
Removal of the Elevator Position Transducer-Unit
AMM 27-92-13-400-001
Installation of the Elevator Position Transducer-Unit
ASM 279408
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-30-00-700-078-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
NOTE: Before you start the operational test procedure, release the FLT CTL/ELAC 1 and FLT CTL/ELAC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-30-00-810-064-B
A. If the test gives the maintenance message:
SEC2 MON OR WIRING TO L G ELEV SERVO VLV 34CE1
   (1) If the fault continues:
     (a) Replace the XDCR UNIT-ELEV POS, L [49CE1] AMM 27-92-13-000-001 and AMM 27-92-13-400-001.
   (2) If the fault continues:
   (3) If the fault continues:
   (4) If the fault continues:
     (a) Do a check of the wiring of the SV XDCR (LVDT) V1 signal from the servocontrol (34CE1) to the SEC 2 (1CE2) ASM 279408:
  • If there is continuity, see Para. (b)
  • If there is no continuity, repair the above wiring.
     (b) Do a check of the wiring of the SV XDCR (LVDT) SPLY signal from the servocontrol (34CE1) to the first terminal block ASM 279408.
  • If there is continuity, see Para. (c)
  • If there is no continuity, repair the above wiring.
     (c) Do a check of the wiring of the POS XDCR MON (RVDT) signal from the transducer unit (49CE1) to the SEC 2 (1CE2) ASM 279408.
  • If there is continuity, see Para. (d)
  • If there is no continuity, repair the above wiring.
     (d) Do a check and repair the wiring of the POS XDCR COM (RVDT) signal from the servocontrol (34CE1) to the SEC 2 (1CE2) ASM 279408.
Subtask 27-30-00-700-079-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:32 UTC