W DOC AIRBUS | TSM A320F

Failure of the Left Elevator Position MON Transducer


TASK 27-30-00-810-814-A
Failure of the Left Elevator Position MON Transducer


1. Possible Causes
  • XDCR UNIT-ELEV POS, L [49CE1]
  • wiring of the POS XDCR MON SPLY signal
  • wiring of the POS XDCR MON V1, V2 signals
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-824-A
Loss of the ACS1 Signal of the ELAC2 MON Side and SEC2 MON Side
TSM TASK 31-32-00-810-933-A
Failure of the Analog Links
AMM 27-92-13-000-001
Removal of the Elevator Position Transducer-Unit
AMM 27-92-13-400-001
Installation of the Elevator Position Transducer-Unit
ASM 279307
ASM 279308
ASM 279407
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-30-00-700-125-A
A. Test
   (1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
L ELEV POS MON XDCR OF ELAC2/SEC2
  • refer to Para. Fault Isolation.
     (b) If the ground scanning gives at least two maintenance messages of the list below:
L B ELEV MODE XDCR 34CE3
L ELEV POS MON XDCR OF ELAC2/SEC2
R B ELEV MODE XDCR 34CE4
R ELEV POS MON XDCR OF ELAC2/SEC2
ELAC2 MON OR INPUT OF THS ACTR XDCR1 9CE
SEC2 MON OR INPUT OF THS ACTR XDCR3 9CE
4. Fault Isolation
Subtask 27-30-00-810-088-C
A. If the test gives the maintenance message L ELEV POS MON XDCR OF ELAC2/SEC2
  • disconnect and cross the electrical connectors of the elevator position transducer unit (49CE1) ASM 279308 and do the test given in Para. 3.
NOTE: After the test connect the electrical connectors on their initial plugs.
   (1) If the fault continues:
   (2) If the test gives the maintenance message L ELEV POS MON XDCR OF ELAC1/SEC1:
   (3) If the test gives the maintenance message L ELEV POS MON XDCR OF ELAC2/SEC2
     (a) Do a check of the wiring of the POS XDCR MON SPLY signal from the transducer unit (49CE1) plug A to the first terminal block ASM 279308:
  • if there is continuity, see Para. (b)
  • if there is no continuity, repair the above wiring.
     (b) Do a check and repair the wiring of the POS XDCR MON V1, V2 signals from the transducer unit (49CE1) plug A to the first terminal block ASM 279308.
Subtask 27-30-00-700-126-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:31 UTC