W DOC AIRBUS | TSM A320F

Failure of the Left Green Elevator-Servocontrol Position-Transducer


TASK 27-30-00-810-812-A
Failure of the Left Green Elevator-Servocontrol Position-Transducer


1. Possible Causes
  • SERVO CTL-L ELEVATOR, INBD G [34CE1]
  • wiring of the POS XDCR COM SPLY signal from the servocontrol (34CE1) to the first terminal block
  • wiring of the POS XDCR COM V1, V2 signals from the servocontrol (34CE1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 27-90-00-810-823-A
Loss of the ACS1 Signal of the ELAC2 COM Side and SEC2 COM Side
TSM TASK 31-32-00-810-933-A
Failure of the Analog Links
AMM 27-34-00-040-001
Elevator Servocontrol Position-Transducer - Connection of the Spare Transducer
AMM 27-34-00-440-001
Reactivation of Elevator Servocontrol Position-Transducer
AMM 27-34-51-000-001
Removal of the Elevator Servo Control
AMM 27-34-51-400-001
Installation of the Elevator Servo Control
ASM 279307
ASM 279308
ASM 279407
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-30-00-700-068-A
A. Test
   (1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
     (a) If the ground scanning gives the maintenance message:
L G ELEV pos XDCR 34CE1 COM E2/S2:USE STBY XDCR
  • refer to Para. Fault Isolation.
     (b) If the ground scanning gives at least two maintenance messages of the list below:
L G ELEV pos XDCR 34CE1 COM E2/S2:USE STBY XDCR
R Y ELEV pos XDCR 34CE2 COM E2/S2:USE STBY XDCR
ELAC2 COM OR INPUT OF THS ACTR XDCR1 9CE
SEC2 COM OR INPUT OF THS ACTR XDCR3 9CE
4. Fault Isolation
Subtask 27-30-00-810-059-A
A. If the test gives the maintenance message:
L G ELEV POS XDCR 34CE1 COM E2/S2 : USE STBY XDCR
   (1) Deactivate the defective RVDT and connect the spare RVDT AMM 27-34-00-040-001 and AMM 27-34-00-440-001.
NOTE: These AMM tasks are only applicable if the servocontrol has a spare RVDT (RVDT triplex or RVDT duplex).
     (a) If the servocontrol has no spare RVDT (RVDT simplex), continue the procedure to the subsequent step (4.A.(2)).
   (2) If the fault continues:
   (3) If the fault continues:
NOTE: The resistance of primary and secondary windings must be between 30 ohms and 500 ohms.
   (4) If the fault continues:
     (a) Do a check of the wiring of the POS XDCR COM SPLY signal from the servocontrol (34CE1) to the first terminal block ASM 279308:
  • if there is continuity, see Para. (b)
  • if there is no continuity, repair the above wiring.
     (b) Do a check and repair the wiring of the POS XDCR COM V1, V2 signals from the servocontrol (34CE1) to the first terminal block ASM 279308.
Subtask 27-30-00-700-069-A
B. Do the tests given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:31 UTC