W DOC AIRBUS | TSM A320F

Loss of the Signal of the Left Blue Elevator-Servocontrol Servovalve by the SEC 1


TASK 27-30-00-810-807-A
Loss of the Signal of the Left Blue Elevator-Servocontrol Servovalve by the SEC 1


1. Possible Causes
  • SEC-1 [1CE1]
  • servovalve
  • wiring of L ELEV SV (ANO 1) signal from the SEC 1 (1CE1) COM part to the MON part
  • wiring from the SEC 1 (1CE1) MON part, pins AD/1F, 1G to the first terminal block
  • wiring of the LVDT SV SPLY signal
  • wiring of the LVDT POS (ANI 3-1) signal
  • SERVO CTL-L ELEVATOR, OUTBD B [34CE3]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-34-51-000-001
Removal of the Elevator Servo Control
AMM 27-34-51-000-008
Removal of the Elevator Servo Control Actuator Servo Valve
AMM 27-34-51-400-001
Installation of the Elevator Servo Control
AMM 27-34-51-400-003
Installation of the Elevator Servo Control Actuator Servo Valve
ASM 279407
AMM 27-94-34-000-001
Removal of the SEC
AMM 27-94-34-400-001
Installation of the SEC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-30-00-700-058-A
A. Test
   (1) Do the operational test of the side stick assembly (Activation for the BITE test) AMM 27-96-00-710-020.
NOTE: Before you start the operational test procedure, release the FLT CTL/ELAC 1, FLT CTL/ELAC 2 and FLT CTL/SEC 2 pushbutton switches (on these pushbutton switches the OFF legends come on).
   (2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-30-00-810-054-A
A. If the test gives the maintenance message:
SEC1 COM OR WIRING TO L B ELEV SERVO VLV 34CE3
   (1) If the fault continues:
   (2) If the fault continues:
     (a) Do a check and repair the wiring of L ELEV SV (ANO 1) signal from the SEC 1 (1CE1) COM part to the MON part, from pins AA/1A, 1B to pins AD/1J, 1K ASM 279407.
     (b) Do a check and repair the wiring from the SEC 1 (1CE1) MON part, pins AD/1F, 1G to the first terminal block ASM 279407.
     (c) Do a check and repair the wiring of the LVDT SV SPLY signal , from the servocontrol (34CE3) to the first terminal block ASM 279407.
     (d) Do a check and repair the wiring of the LVDT POS (ANI 3-1) signal, from the SEC 1 (1CE1) MON part to the servocontrol (34CE3) ASM 279407.
   (3) If the fault continues:
Subtask 27-30-00-700-059-A
B. Do the tests given in Para. 3.