Results of the Operational Test of the Rudder Servocontrols with Individual Hydraulic System not Satisfactory
TASK 27-20-00-810-807-A
Results of the Operational Test of the Rudder Servocontrols with Individual Hydraulic System not Satisfactory
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 27-20-00-710-056-A
Subtask 27-20-00-810-056-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:29 UTC
Results of the Operational Test of the Rudder Servocontrols with Individual Hydraulic System not Satisfactory
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-24-00-710-002 | Operational Test of the Rudder Servocontrols with Individual Hydraulic System |
| AMM 27-24-00-820-001 | Adjustment of the Rudder Neutral Position |
Subtask 27-20-00-710-056-A
A. Test
(1) Do the operational test of the rudder servocontrols with individual hydraulic system AMM 27-24-00-710-002.
4. Fault Isolation(1) Do the operational test of the rudder servocontrols with individual hydraulic system AMM 27-24-00-710-002.
Subtask 27-20-00-810-056-A
A. On the lower ECAM display unit, on the F/CTL page:
(1) if the pointer of the RUD indicator does not go back to the neutral position:
Subtask 27-20-00-710-057-A (1) if the pointer of the RUD indicator does not go back to the neutral position:
- do the adjustment of the rudder actuating spring rod AMM 27-24-00-820-001.
- make sure that there is no warning related to rudder travel limitation.
B. Do the test given in Para. 3.