W DOC AIRBUS | TSM A320F

Loss of the Servovalve Signal for the Right Blue Aileron Servo Control


TASK 27-10-00-810-828-A
Loss of the Servovalve Signal for the Right Blue Aileron Servo Control


1. Possible Causes
  • ELAC-2 [2CE2]
  • servovalve
  • wiring of the SV signal from the servo control (33CE4) to the ELAC 2 (2CE2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 27-14-51-000-003
Removal of the Aileron Servo-Control Servovalve
AMM 27-14-51-400-003
Installation of the Aileron Servo-Control Servovalve
ASM 279303
AMM 27-93-34-000-001
Removal of the ELAC
AMM 27-93-34-400-001
Installation of the ELAC
AMM 27-96-00-710-020
Operational Test of the Side Stick Assembly (Activation for the BITE Test)
AMM 27-96-00-740-001
BITE Test of the EFCS (Ground Scanning)
3. Fault Confirmation
Subtask 27-10-00-700-091-A
A. Test
   (1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
   (2) Do the BITE test of the EFCS (Ground Scanning) AMM 27-96-00-740-001.
4. Fault Isolation
Subtask 27-10-00-810-077-A
A. If the test gives the maintenance message:
R B AIL SERVO VLV 33CE4 OR OUTPUT FROM ELAC 2
   (1) If the fault continues:
NOTE: The resistance must be 500 ohms +/- 10 %.
   (2) If the fault continues:
  • do a check and repair the wiring of the SV signal from the servo control (33CE4) to the ELAC 2 (2CE2), ASM 279303.
Subtask 27-10-00-700-092-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:28 UTC