Loss of the Right Blue Aileron Position Transducer Signal for the ELAC 2
TASK 27-10-00-810-827-A
Loss of the Right Blue Aileron Position Transducer Signal for the ELAC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-10-00-700-089-A
Subtask 27-10-00-810-076-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:28 UTC
Loss of the Right Blue Aileron Position Transducer Signal for the ELAC 2
1. Possible Causes
- ELAC-2 [2CE2]
wiring of the ANI 2-4, POS SV R AIL signal from the ELAC 2 (2CE2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 279303 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-10-00-700-089-A
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
Subtask 27-10-00-810-076-A
A. If the test gives the maintenance message:
ELAC 2 COM OR WIRING FROM R B AIL POS XDCR 33CE4
or
ELAC 2 MON OR WIRING FROM R B AIL POS XDCR 33CE4
(a) Do a check and repair thewiring of the ANI 2-4, POS SV R AIL signal from the ELAC 2 (2CE2) to the first terminal block , COM or MON part as shown in the maintenance message ASM 279303.
Subtask 27-10-00-700-090-A ELAC 2 COM OR WIRING FROM R B AIL POS XDCR 33CE4
or
ELAC 2 MON OR WIRING FROM R B AIL POS XDCR 33CE4
- replace the ELAC-2 [2CE2] , AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
(a) Do a check and repair the
B. Do the test given in Para. 3.