Loss of the Servovalve Signal for the Left Green Aileron Servo Control
TASK 27-10-00-810-815-A
Loss of the Servovalve Signal for the Left Green Aileron Servo Control
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 27-10-00-700-071-A
Subtask 27-10-00-810-064-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:27 UTC
Loss of the Servovalve Signal for the Left Green Aileron Servo Control
1. Possible Causes
- ELAC-2 [2CE2]
- servovalve
wiring of the SV signal from the servo control (33CE1) to the ELAC 2 (2CE2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 27-14-51-000-003 | Removal of the Aileron Servo-Control Servovalve |
| AMM 27-14-51-400-003 | Installation of the Aileron Servo-Control Servovalve |
| ASM 279303 | |
| AMM 27-93-34-000-001 | Removal of the ELAC |
| AMM 27-93-34-400-001 | Installation of the ELAC |
| AMM 27-96-00-710-020 | Operational Test of the Side Stick Assembly (Activation for the BITE Test) |
| AMM 27-96-00-740-001 | BITE Test of the EFCS (Ground Scanning) |
Subtask 27-10-00-700-071-A
A. Test
(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
4. Fault Isolation(1) Do the operational test of the side stick assembly (activation for the BITE test) AMM 27-96-00-710-020.
(2) Do the BITE test of the EFCS (ground scanning) AMM 27-96-00-740-001.
Subtask 27-10-00-810-064-A
A. If the test gives the maintenance message:
L G AIL SERVO VLV 33CE1 OR OUTPUT FROM ELAC 2
Subtask 27-10-00-700-072-A L G AIL SERVO VLV 33CE1 OR OUTPUT FROM ELAC 2
- Replace the ELAC-2 [2CE2] , AMM 27-93-34-000-001 and AMM 27-93-34-400-001.
- Replace the servovalve of the aileron servo control (33CE1), AMM 27-14-51-000-003 and AMM 27-14-51-400-003.
- Do a check and repair the
wiring of the SV signal from the servo control (33CE1) to the ELAC 2 (2CE2) , ASM 279303.
B. Do the test given in Para. 3.