LDCC BTL 1 FWD SQUIB Fault
TASK 26-23-00-810-806-A
LDCC BTL 1 FWD SQUIB Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-23-00-710-055-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 26-23-00-810-055-A ** ON A/C NOT FOR ALL
Subtask 26-23-00-860-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:25 UTC
LDCC BTL 1 FWD SQUIB Fault
1. Possible Causes
CARTRIDGE FWD, BOTTLE 1 P/BSW DISH (3WX) - SDCU [10WQ]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 26-17-34-000-001 | Removal of the Smoke-Detection Control Unit (SDCU) |
| AMM 26-17-34-400-001 | Installation of the Smoke-Detection Control Unit (SDCU) |
| AMM 26-23-00-710-001 | Operational Test of the Cargo-Compartment Fire-Extinguishing System |
| ASM 262301 | |
| AMM 26-23-41-000-005 | Removal of the Cartridge of the Cargo Fire-Extinguisher Bottle |
| AMM 26-23-41-400-005 | Installation of the Cartridge of the Cargo Fire-Extinguisher Bottle |
Subtask 26-23-00-710-055-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 26-23-00-810-055-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-23-00-810-061-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message CRG FIRE BTL 1 FWD SQUIB:
Subtask 26-23-00-810-061-E ** ON A/C NOT FOR ALL - replace the
CARTRIDGE FWD, BOTTLE 1 AMM 26-23-41-000-005 and AMM 26-23-41-400-005.
- do a check of the
P/BSW DISH (3WX) and replace it if necessary ASM 262301.
- replace the SDCU [10WQ] AMM 26-17-34-000-001 and AMM 26-17-34-400-001.
- do a check and repair the wiring between the:
BOTTLE 1 (4005WX) connector C/B and SDCU (10WQ) connector AA/11A,
BOTTLE 1 (4005WX) connector C/A and GND ASM 262301.
B. If the test gives the maintenance message CRG FIRE BTL 1 FWD SQUIB:
Subtask 26-23-00-710-061-A ** ON A/C NOT FOR ALL - replace the
CARTRIDGE FWD, BOTTLE 1 AMM 26-23-41-000-005 and AMM 26-23-41-400-005.
- do a check of the
P/BSW DISH (3WX) and replace it if necessary ASM 262301.
- replace the SDCU [10WQ] AMM 26-17-34-000-001 and AMM 26-17-34-400-001.
- do a check and repair the wiring between the:
BOTTLE 1 (4015WX) connector C/B and SDCU (10WQ) connector AA/11A,
BOTTLE 1 (4015WX) connector C/A and GND ASM 262301.
C. Do the test given in Para. 3.
5. Close-upSubtask 26-23-00-860-055-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.