The DISCH Legend of the ENG 1/AGENT 2 Pushbutton Switch does not Come on
TASK 26-21-00-810-812-A
The DISCH Legend of the ENG 1/AGENT 2 Pushbutton Switch does not Come on
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-21-00-865-059-A
Subtask 26-21-00-810-061-A
Subtask 26-21-00-860-059-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:24 UTC
The DISCH Legend of the ENG 1/AGENT 2 Pushbutton Switch does not Come on
1. Possible Causes
lamp of the DISCH legend of the ENG 1/AGENT 2 pushbutton switch ENG 1/AGENT 2 pushbutton switch - ENG/APU FIRE PNL [1WD]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2045110 | |
| AMM 26-12-00-710-001 | Operational Check of Loop/Squib |
| AMM 26-12-12-000-001 | Removal of the ENG/APU Fire Panel |
| AMM 26-12-12-400-001 | Installation of the ENG/APU Fire Panel |
Subtask 26-21-00-865-059-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 26-21-00-710-072-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | LIGHTING/TST/BOARD/SPLY | 30LP | X06 |
B. Test
(1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
4. Fault Isolation(1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
Subtask 26-21-00-810-061-A
A. If the DISCH legend of the ENG 1/AGENT 2 pushbutton switch does not come on during the fire test:
(a) Replace thelamp of the DISCH legend of the ENG 1/AGENT 2 pushbutton switch .
(2) If the DISCH legend comes on:
Subtask 26-21-00-710-073-A - on the panel 25VU, set the ANN LT switch to TEST, and do a check to see if the DISCH legend of the ENG 1/AGENT 2 pushbutton switch comes on.
(a) Replace the
- If the fault continues: replace the
ENG 1/AGENT 2 pushbutton switch .
(2) If the DISCH legend comes on:
- replace the ENG/APU FIRE PNL [1WD] AMM 26-12-12-000-001 and AMM 26-12-12-400-001.
B. Do the test given in Para. 3.
5. Close-upSubtask 26-21-00-860-059-A
A. Put the aircraft back to its initial configuration.
(1) On the panel 25VU, set the ANN LT switch to BRT.
(1) On the panel 25VU, set the ANN LT switch to BRT.