W DOC AIRBUS | TSM A320F

The SQUIB and DISCH Legends of the ENG 1/AGENT 2 Pushbutton Switch do not Come on


TASK 26-21-00-810-808-A
The SQUIB and DISCH Legends of the ENG 1/AGENT 2 Pushbutton Switch do not Come on


1. Possible Causes
  • lamps of the ENG 1/AGENT 2 pushbutton switch
  • ENG 1/AGENT 2 pushbutton switch
  • wiring of the 5VAC signal at the ENG 1/AGENT 2 pushbutton switch
  • wiring of the ground signal at the ENG 1/AGENT 2 pushbutton switch
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ESPM 2045110
AMM 26-12-00-710-001
Operational Check of Loop/Squib
ASM 262101
3. Fault Confirmation
Subtask 26-21-00-865-055-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/TST/BOARD/SPLY30LPX06
Subtask 26-21-00-710-064-A
B. Test
   (1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
4. Fault Isolation
Subtask 26-21-00-810-057-A
A. If the SQUIB and DISCH legends of the ENG 1/AGENT 2 pushbutton switch do not come on during the fire test:
  • on the panel 25VU, set the ANN LT switch to TEST and do a check to see if the SQUIB and DISCH legends come on.
   (1) If the SQUIB and DISCH legends do not come on:
     (a) Replace the lamps of the ENG 1/AGENT 2 pushbutton switch.
  • If the fault continues: replace the ENG 1/AGENT 2 pushbutton switch.
     (b) Or replace the ENG 1/AGENT 2 pushbutton switch that has LEDs ESPM 2045110.
     (c) If the fault continues:
  • do a check and repair the wiring of the 5VAC signal at the ENG 1/AGENT 2 pushbutton switch from the ENG/APU FIRE panel (1WD) pin B/C to the first terminal block ASM 262101.
   (2) If the SQUIB and DISCH legends come on:
  • do a check and repair the wiring of the ground signal at the ENG 1/AGENT 2 pushbutton switch on the ENG/APU FIRE panel pin B/D ASM 262101 .
Subtask 26-21-00-710-065-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 26-21-00-860-055-A
A. Put the aircraft back to its initial configuration.
   (1) On the panel 25VU, set the ANN LT switch to BRT.
[Rev.8 from Aug 2018] 2026.04.04 04:27:23 UTC