W DOC AIRBUS | TSM A320F

The SQUIB Legends of the ENG 1 and ENG 2/AGENT 2 Pushbutton Switches do not Come on


TASK 26-21-00-810-806-A
The SQUIB Legends of the ENG 1 and ENG 2/AGENT 2 Pushbutton Switches do not Come on


1. Possible Causes
  • ENG/APU FIRE PNL [1WD]
  • C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A [1WE2]
  • C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B [2WE2]
  • C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B [2WE1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-12-00-710-001
Operational Check of Loop/Squib
AMM 26-12-12-000-001
Removal of the ENG/APU Fire Panel
AMM 26-12-12-400-001
Installation of the ENG/APU Fire Panel
3. Fault Confirmation
Subtask 26-21-00-710-060-A
A. Test
   (1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
4. Fault Isolation
Subtask 26-21-00-810-055-A ** ON A/C NOT FOR ALL
A. If the SQUIB legends of the ENG 1 and ENG 2/AGENT 2 pushbutton switches do not come on during the fire test:
   (1) If the fault continues:
  • replace the C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A [1WE2] .
   (2) If the fault continues:
  • replace the C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B [2WE2] .
Subtask 26-21-00-810-055-B ** ON A/C NOT FOR ALL
A. If the SQUIB legends of the ENG 1 and ENG 2/AGENT 2 pushbutton switches do not come on during the fire test:
   (1) If the fault continues:
  • Replace C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A [1WE2] .
   (2) If the fault continues:
  • Replace C/B-ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B [2WE1] .
Subtask 26-21-00-710-061-A
B. Do the test given in Para. 3.