W DOC AIRBUS | TSM A320F

No data from CFDS


TASK 26-17-00-810-832-A
No data from CFDS


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 237303
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 26-10-00-740-802
Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF)
AMM 31-32-00-740-002
BITE Test of the Centralized Fault Display Interface Unit (CFDIU)
3. Fault Confirmation
Subtask 26-17-00-865-065-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
Subtask 26-17-00-740-051-A ** ON A/C NOT FOR ALL
B. Test
   (1) Open the circuit breakers 14WH, 15WH, 17WH and 18WH.
   (2) After 10s, close the circuit breakers again.
   (3) After a minimum time of 30s, do the Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
   (4) Do the BITE Test of the Centralized Fault Display Interface Unit (CFDIU) AMM 31-32-00-740-002.
4. Fault Isolation
Subtask 26-17-00-810-153-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDS1 (1TM1)/CIDS(101RH)-SDF1 or CFDS1 (1TM1)/CIDS(102RH)-SDF2:
  • Do a check and repair the wiring between the related CIDS director
    DIR-CIDS, 1 [101RH] or DIR-CIDS, 2 [102RH] connector AA pin 11G and 11H to CFDIU [1TW] ASM 237303.
   (1) If the fault continues:
Subtask 26-17-00-710-111-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
5. Close-up
Subtask 26-17-00-860-080-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:27:22 UTC