Unexpected Smoke Detector
TASK 26-17-00-810-830-A
Unexpected Smoke Detector
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-865-063-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-810-149-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-078-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:08 UTC
Unexpected Smoke Detector
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 237303 | |
| AMM 23-73-19-000-002 | Removal of the Cabin Assignment Module |
| AMM 23-73-19-400-002 | Installation of the Cabin Assignment Module |
| AMM 26-10-00-740-802 | Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) |
| ASM 261602 | |
| AMM 26-16-15-000-001 | Removal of the Cargo-Compartment Smoke Detectors |
| AMM 26-16-15-400-001 | Installation of the Cargo-Compartment Smoke Detectors |
Subtask 26-17-00-865-063-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 26-17-00-740-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CIDS/SDF/DIR2 ESS | 18WH | C06 |
| 49VU | AIR COND/CIDS/SDF/DIR1 ESS | 15WH | C05 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/2 | 14WH | T18 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/1 | 17WH | T17 |
B. Test
(1) Open the circuit breakers 14WH, 15WH, 17WH and 18WH.
(2) After 10 seconds, close the circuit breakers again.
(3) After a minimum time of 30 seconds, do the Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
4. Fault Isolation(1) Open the circuit breakers 14WH, 15WH, 17WH and 18WH.
(2) After 10 seconds, close the circuit breakers again.
(3) After a minimum time of 30 seconds, do the Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
Subtask 26-17-00-810-149-A ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message which is different from the maintenance message given in Para 4.B.:
Subtask 26-17-00-810-150-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives this maintenance message WRG: SMK DET ADDRESS:
(1) If the test additionally gives a maintenance message WRG: CAN BUS x/ SMK DET FWD LDCC (yWH) or WRG: CAN BUS x/ SMK DET AFT LDCC (yWH), check the pin programming of the smoke detector yWH, pins F,G,H,J,K,S and T ASM 261602.
(3) If the fault continues:
Subtask 26-17-00-810-155-A ** ON A/C NOT FOR ALL (1) If the test additionally gives a maintenance message WRG: CAN BUS x/ SMK DET FWD LDCC (yWH) or WRG: CAN BUS x/ SMK DET AFT LDCC (yWH), check the pin programming of the smoke detector yWH, pins F,G,H,J,K,S and T ASM 261602.
NOTE: yWH is the FIN of the related smoke detector.
(2) Do a check of the pin programming of the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] connector AB , pins 11H, 12H, 11K,9H and 10H to the ground/ to open contact ASM 237303. (3) If the fault continues:
- Do a check of the pin programming for all smoke detectors, pins F,G,H,J,K,S and T connected to CAN Bus A and B ASM 261602.
C. If the fault continues:
(1) Make sure that the Cabin Assignment Module (CAM) is applicable to the cabin layout (number and location of the lavatories).
(2) Replace the MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-000-002 and AMM 23-73-19-400-002.
(3) Do the test given in Para. 3.
Subtask 26-17-00-810-156-A ** ON A/C NOT FOR ALL (1) Make sure that the Cabin Assignment Module (CAM) is applicable to the cabin layout (number and location of the lavatories).
(2) Replace the MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-000-002 and AMM 23-73-19-400-002.
(3) Do the test given in Para. 3.
D. If the fault continues:
(1) Replace the related cargo-compartment smoke detector AMM 26-16-15-000-001 and AMM 26-16-15-400-001.
5. Close-up(1) Replace the related cargo-compartment smoke detector AMM 26-16-15-000-001 and AMM 26-16-15-400-001.
Subtask 26-17-00-860-078-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.