W DOC AIRBUS | TSM A320F

Unexpected Smoke Detector


TASK 26-17-00-810-830-A
Unexpected Smoke Detector


1. Possible Causes
  • smoke detector
  • DIR-CIDS, 1 [101RH]
  • DIR-CIDS, 2 [102RH]
  • connector AB
  • MODULE-CABIN ASSIGNMENT [115RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 237303
AMM 23-73-19-000-002
Removal of the Cabin Assignment Module
AMM 23-73-19-400-002
Installation of the Cabin Assignment Module
AMM 26-10-00-740-802
Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF)
ASM 261602
AMM 26-16-15-000-001
Removal of the Cargo-Compartment Smoke Detectors
AMM 26-16-15-400-001
Installation of the Cargo-Compartment Smoke Detectors
3. Fault Confirmation
Subtask 26-17-00-865-063-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
Subtask 26-17-00-740-050-A ** ON A/C NOT FOR ALL
B. Test
   (1) Open the circuit breakers 14WH, 15WH, 17WH and 18WH.
   (2) After 10 seconds, close the circuit breakers again.
   (3) After a minimum time of 30 seconds, do the Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
4. Fault Isolation
Subtask 26-17-00-810-149-A ** ON A/C NOT FOR ALL
A. If the test gives a maintenance message which is different from the maintenance message given in Para 4.B.:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-17-00-810-150-A ** ON A/C NOT FOR ALL
B. If the test gives this maintenance message WRG: SMK DET ADDRESS:
   (1) If the test additionally gives a maintenance message WRG: CAN BUS x/ SMK DET FWD LDCC (yWH) or WRG: CAN BUS x/ SMK DET AFT LDCC (yWH), check the pin programming of the smoke detector yWH, pins F,G,H,J,K,S and T ASM 261602.
NOTE: yWH is the FIN of the related smoke detector.
   (2) Do a check of the pin programming of the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] connector AB , pins 11H, 12H, 11K,9H and 10H to the ground/ to open contact ASM 237303.
   (3) If the fault continues:
  • Do a check of the pin programming for all smoke detectors, pins F,G,H,J,K,S and T connected to CAN Bus A and B ASM 261602.
   (4) Do the test given in Para. 3.
Subtask 26-17-00-810-155-A ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) Make sure that the Cabin Assignment Module (CAM) is applicable to the cabin layout (number and location of the lavatories).
   (2) Replace the MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-000-002 and AMM 23-73-19-400-002.
   (3) Do the test given in Para. 3.
Subtask 26-17-00-810-156-A ** ON A/C NOT FOR ALL
D. If the fault continues:
   (1) Replace the related cargo-compartment smoke detector AMM 26-16-15-000-001 and AMM 26-16-15-400-001.
5. Close-up
Subtask 26-17-00-860-078-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:27:22 UTC