CAM Version Fault between CAM in FAP and internally stored SDF CAM
TASK 26-17-00-810-829-A
CAM Version Fault between CAM in FAP and internally stored SDF CAM
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-710-106-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-865-062-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-077-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:22 UTC
CAM Version Fault between CAM in FAP and internally stored SDF CAM
1. Possible Causes
- MODULE-CABIN ASSIGNMENT [115RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-19-960-001 | Replacement of the Cabin Assignment Module |
| AMM 26-10-00-710-801 | Smoke Detection Function Cabin Assignment Module (SDF CAM) Layout Loading |
| AMM 26-10-00-740-802 | Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) |
Subtask 26-17-00-710-106-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the ground scanning of the Cabin Intercommunication Data System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
4. Fault Isolation(1) Do the ground scanning of the Cabin Intercommunication Data System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
Subtask 26-17-00-865-062-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 26-17-00-810-147-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CIDS/SDF/DIR2 ESS | 18WH | C06 |
| 49VU | AIR COND/CIDS/SDF/DIR1 ESS | 15WH | C05 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/2 | 14WH | T18 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/1 | 17WH | T17 |
B. If the test gives a maintenance message which is different from the maintenance message given in step C:
Subtask 26-17-00-810-148-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
C. If the test gives the maintenance message
(a) If the CAM version is wrong:
1 Open the circuit breakers 14WH, 15WH, 17WH and 18WH.
2 Close the circuit breakers 17WH and 18WH to start manually a SDF CAM dataloading without an aircraft layout change.
4 All alerts and failure messages go off.
Subtask 26-17-00-810-148-B ** ON A/C NOT FOR ALL - CAM(115RH)/ SDF CAM ID MISMATCH:
(a) If the CAM version is wrong:
- Install the related MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-960-001.
1 Open the circuit breakers 14WH, 15WH, 17WH and 18WH.
2 Close the circuit breakers 17WH and 18WH to start manually a SDF CAM dataloading without an aircraft layout change.
NOTE: During SDF power up, alerts of the smoke detection systems are shown on the ECAM/Warning Display.
3 After approximately 5 minutes, close the circuit breakers 14WH and 15WH. 4 All alerts and failure messages go off.
C. If the test gives the maintenance message
(a) If the CAM version is wrong:
Subtask 26-17-00-710-107-A ** ON A/C NOT FOR ALL - CAM(115RH)/ SDF CAM ID MISMATCH:
(a) If the CAM version is wrong:
- Install the related MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-960-001.
- Do the Smoke-Detection Function-Cabin Assignment-Module (SDF CAM) layout loading AMM 26-10-00-710-801.
D. Test
(1) Do the test given in Para. 3.
5. Close-up(1) Do the test given in Para. 3.
Subtask 26-17-00-860-077-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Put the aircraft back to its initial configuration.
(1) Put the aircraft back to its initial configuration.