W DOC AIRBUS | TSM A320F

CIDS-SDF Channel 1 and/or 2 Failure


TASK 26-17-00-810-823-A
CIDS-SDF Channel 1 and/or 2 Failure


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 237301
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 26-10-00-740-802
Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF)
ASM 261602
AWM 315219
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 26-17-00-865-059-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
Subtask 26-17-00-710-092-B ** ON A/C NOT FOR ALL
B. Test
   (1) Do the SYSTEM TEST of the CIDS-SDF system.
     (a) On the MCDU:
  • Set the "SYSTEM REPORT / TEST" page.
  • Set the "FIRE PROT" page.
  • Set the "SMOKE" (or "SDCU" and on the subsequent page "NEXT PAGE" as specified by the installed CFDIU-standard) page.
  • Set the "SYSTEM TEST" page in the CIDS-SDF menu.
4. Fault Isolation
Subtask 26-17-00-810-127-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-17-00-810-128-B ** ON A/C NOT FOR ALL
B. One of these procedures is applicable:
   (1) If the test gives the maintenance message: CHECK SDF1 BITE/CIDS(101RH)-SDF1 or CHECK SDF2 BITE/CIDS(102RH)-SDF2:
     (a) For the maintenance message CHECK SDF2 BITE/CIDS(102RH)-SDF2:
       1 Open the C/B 15WH and 17WH of the CIDS-SDF1:
  • On the MCDU the CIDS - SDF2 comes on.
       2 On the MCDU:
         a Do the Ground Scanning and read out the last Leg Report of the CIDS-SDF2 AMM 26-10-00-740-802.
         b If the reports show a failure of the smoke board 2 of the DIR-CIDS, 2 [102RH] :
         c If the reports show a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
     (b) For the maintenance message CHECK SDF1 BITE/CIDS(101RH)-SDF1:
       1 Open the C/B 14WH and 18WH of the CIDS-SDF2:
  • On the MCDU the CIDS - SDF1 comes on.
       2 On the MCDU:
         a Do the Ground Scanning and read out the last Leg Report of the CIDS-SDF1 AMM 26-10-00-740-802.
         b If the reports show a failure of the smoke board 1 of the DIR-CIDS, 1 [101RH] :
         c If the reports show a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) If the test gives the maintenance message CIDS(101RH)-SDF1 and / or CIDS(102RH)-SDF2:
   (3) If the test gives the maintenance message: CIDS(102RH)-SDF2 BUS / CIDS(101RH)-SDF1 in relation with FWC1: NO DATA FROM CIDS-SDF1 and / or FWC2: NO DATA FROM CIDS-SDF2:
  • Do a check and repair the wiring between the CIDS Directors (pins AA11J/AA11K and AA15C/AA15H) ASM 237301.
     (a) If the PFR-message is FWC1: NO DATA FROM CIDS-SDF1 and/or FWC2: NO DATA FROM CIDS-SDF1:
  • Do a check and repair the wiring between the related FWC and the CIDS-SDF channels AWM 315219.
     (b) If the fault continues:
  • Do a check and repair the wiring between the circuit breakers 15WH and 17WH and the CIDS Director 1 (101RH) AC/9 and AC/10 ASM 261602.
  • Do a check and repair the wiring between the circuit breakers 14WH and 18WH and the CIDS Director 2 (102RH) AC/9 and AC/10 ASM 261602.
   (4) If the test gives the maintenance message CIDS(101RH)-SDF1 and CIDS(102RH)-SDF2 in relation with SMOKE DET FAULT:
     (a) Replace the DIR-CIDS, 101RH and/or DIR-CIDS 102RH AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
     (b) If the fault continues:
  • Do a check and repair the wiring between the circuit breakers 15WH and 17WH and the CIDS Director 1 (101RH) AC/9 and AC/10 ASM 261602.
  • Do a check and repair the wiring between the circuit breakers 14WH and 18WH and the CIDS Director 2 (102RH) AC/9 and AC/10 ASM 261602.
     (c) If the fault continues:
     (d) If the fault continues:
  • Do a check and repair the wiring between the CIDS1-SDF and the FWC1 and/or FWC2 AWM 315219.
  • Do a check and repair the wiring between the CIDS2-SDF and the FWC1 and/or FWC2 AWM 315219.
Subtask 26-17-00-710-093-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
5. Close-up
Subtask 26-17-00-860-070-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:27:22 UTC