CIDS-SDF Channel 1 and/or 2 Failure
TASK 26-17-00-810-823-A
CIDS-SDF Channel 1 and/or 2 Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-865-059-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-810-127-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-070-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:22 UTC
CIDS-SDF Channel 1 and/or 2 Failure
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 237301 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 26-10-00-740-802 | Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) |
| ASM 261602 | |
| AWM 315219 | |
| AMM 31-53-34-000-001 | Removal of the Flight Warning Computer (FWC) |
| AMM 31-53-34-400-001 | Installation of the Flight Warning Computer (FWC) |
Subtask 26-17-00-865-059-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 26-17-00-710-092-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/CIDS/SDF/DIR2 ESS | 18WH | C06 |
| 49VU | AIR COND/CIDS/SDF/DIR1 ESS | 15WH | C05 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/2 | 14WH | T18 |
| 122VU | AIR COND/CIDS/SDF/DIR NORM/1 | 17WH | T17 |
B. Test
(1) Do the SYSTEM TEST of the CIDS-SDF system.
(a) On the MCDU:
4. Fault Isolation(1) Do the SYSTEM TEST of the CIDS-SDF system.
(a) On the MCDU:
- Set the "SYSTEM REPORT / TEST" page.
- Set the "FIRE PROT" page.
- Set the "SMOKE" (or "SDCU" and on the subsequent page "NEXT PAGE" as specified by the installed CFDIU-standard) page.
- Set the "SYSTEM TEST" page in the CIDS-SDF menu.
Subtask 26-17-00-810-127-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-17-00-810-128-B ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. One of these procedures is applicable:
(1) If the test gives the maintenance message: CHECK SDF1 BITE/CIDS(101RH)-SDF1 or CHECK SDF2 BITE/CIDS(102RH)-SDF2:
(a) For the maintenance message CHECK SDF2 BITE/CIDS(102RH)-SDF2:
1 Open the C/B 15WH and 17WH of the CIDS-SDF1:
a Do the Ground Scanning and read out the last Leg Report of the CIDS-SDF2 AMM 26-10-00-740-802.
b If the reports show a failure of the smoke board 2 of the DIR-CIDS, 2 [102RH] :
1 Open the C/B 14WH and 18WH of the CIDS-SDF2:
a Do the Ground Scanning and read out the last Leg Report of the CIDS-SDF1 AMM 26-10-00-740-802.
b If the reports show a failure of the smoke board 1 of the DIR-CIDS, 1 [101RH] :
(a) Replace the DIR-CIDS, 101RH and/or DIR-CIDS 102RH AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(b) If the fault continues:
Subtask 26-17-00-710-093-A ** ON A/C NOT FOR ALL (1) If the test gives the maintenance message: CHECK SDF1 BITE/CIDS(101RH)-SDF1 or CHECK SDF2 BITE/CIDS(102RH)-SDF2:
(a) For the maintenance message CHECK SDF2 BITE/CIDS(102RH)-SDF2:
1 Open the C/B 15WH and 17WH of the CIDS-SDF1:
- On the MCDU the CIDS - SDF2 comes on.
a Do the Ground Scanning and read out the last Leg Report of the CIDS-SDF2 AMM 26-10-00-740-802.
b If the reports show a failure of the smoke board 2 of the DIR-CIDS, 2 [102RH] :
- Replace the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 AMM 23-73-34-400-001.
- Do the trouble shooting procedure related to the maintenance message.
1 Open the C/B 14WH and 18WH of the CIDS-SDF2:
- On the MCDU the CIDS - SDF1 comes on.
a Do the Ground Scanning and read out the last Leg Report of the CIDS-SDF1 AMM 26-10-00-740-802.
b If the reports show a failure of the smoke board 1 of the DIR-CIDS, 1 [101RH] :
- Replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 AMM 23-73-34-400-001.
- Do the trouble shooting procedure related to the maintenance message.
- Replace the DIR-CIDS, 1 [101RH] and / or DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- Do a check and repair the wiring between the CIDS Directors (pins AA11J/AA11K and AA15C/AA15H) ASM 237301.
- Do a check and repair the wiring between the related FWC and the CIDS-SDF channels AWM 315219.
- Do a check and repair the wiring between the circuit breakers 15WH and 17WH and the CIDS Director 1 (101RH) AC/9 and AC/10 ASM 261602.
- Do a check and repair the wiring between the circuit breakers 14WH and 18WH and the CIDS Director 2 (102RH) AC/9 and AC/10 ASM 261602.
(a) Replace the DIR-CIDS, 101RH and/or DIR-CIDS 102RH AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(b) If the fault continues:
- Do a check and repair the wiring between the circuit breakers 15WH and 17WH and the CIDS Director 1 (101RH) AC/9 and AC/10 ASM 261602.
- Do a check and repair the wiring between the circuit breakers 14WH and 18WH and the CIDS Director 2 (102RH) AC/9 and AC/10 ASM 261602.
- Replace the Flight Warning Computer FWC1 and/or FWC2 AMM 31-53-34-000-001 and AMM 31-53-34-400-001.
- Do a check and repair the wiring between the CIDS1-SDF and the FWC1 and/or FWC2 AWM 315219.
- Do a check and repair the wiring between the CIDS2-SDF and the FWC1 and/or FWC2 AWM 315219.
C. Do the test given in Para. 3.
5. Close-upSubtask 26-17-00-860-070-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.