Communication RS232 to CIDS Mainboard failed


TASK 26-17-00-810-822-A
Communication RS232 to CIDS Mainboard failed


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 26-10-00-740-801
BITE Test of the Smoke Detection Function - System Test
3. Fault Confirmation
Subtask 26-17-00-710-090-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the smoke detection function - system test AMM 26-10-00-740-801.
4. Fault Isolation
Subtask 26-17-00-810-124-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-17-00-810-125-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message
DIR1(101RH)-SDF, SDF1(101RH)-DIR1(101RH), DIR2(102RH)-SDF or SDF2(102RH)-DIR2(102RH):
Subtask 26-17-00-710-091-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
5. Close-up
Subtask 26-17-00-860-069-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.