W DOC AIRBUS | TSM A320F

Unexpected Lavatory Smoke-Detector


TASK 26-17-00-810-821-A
Unexpected Lavatory Smoke-Detector


1. Possible Causes
  • smoke detectors
  • MODULE-CABIN ASSIGNMENT [115RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-19-000-002
Removal of the Cabin Assignment Module
AMM 23-73-19-400-002
Installation of the Cabin Assignment Module
ASM 261701
3. Fault Confirmation
Subtask 26-17-00-710-088-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 26-17-00-810-121-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-17-00-810-157-A ** ON A/C NOT FOR ALL
B. If the test gives this maintenance message WRG: SMK DET ADDRESS:
   (1) If the test additionally gives a maintenance message WRG: CAN BUS/ SMK DET LAV x, check the pin programming of the related smoke detector, pins F,G,H,J,K,S and T ASM 261701
NOTE: x is the location of the related smoke detector.
   (2) If the fault continues:
  • Do a check of the pin programming for all lavatory smoke detectors , pins F,G,H,J,K,S and T ASM 261701.
Subtask 26-17-00-810-122-A ** ON A/C NOT FOR ALL
C. If the test confirms the fault:
Subtask 26-17-00-710-089-A ** ON A/C NOT FOR ALL
D. Do the test as given in the Para. 3.
5. Close-up
Subtask 26-17-00-860-068-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.