Lavatory Smoke-Detector Contamination
TASK 26-17-00-810-816-A
Lavatory Smoke-Detector Contamination
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-710-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 26-17-00-810-103-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-062-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:21 UTC
Lavatory Smoke-Detector Contamination
1. Possible Causes
- lavatory smoke detector
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 26-17-00-710-001 | Operational Test of the Lavatory Smoke-Detection System |
| AMM 26-17-15-000-001 | Removal of the Lavatory Smoke Detector |
| AMM 26-17-15-000-008 | Removal of the Lavatory Smoke Detector |
| AMM 26-17-15-000-802 | Removal of the Smoke Detector of Lavatory A |
| AMM 26-17-15-000-808 | Removal of the Smoke Detector of Lavatory DS/ES/HS |
| AMM 26-17-15-000-809 | Removal of the Smoke Detector of Lavatory WC/FS/GS |
| AMM 26-17-15-400-001 | Installation of the Lavatory Smoke Detector |
| AMM 26-17-15-400-007 | Installation of the Lavatory Smoke Detector |
| AMM 26-17-15-400-802 | Installation of the Smoke Detector of Lavatory A |
| AMM 26-17-15-400-808 | Installation of the Smoke Detector of Lavatory DS/ES/HS |
| AMM 26-17-15-400-809 | Installation of the Smoke Detector of Lavatory WC/FS/GS |
Subtask 26-17-00-710-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 26-17-00-810-103-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-17-00-810-110-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message SMOKE DET LAV X CONTAMINATION (X = location of the related lavatory)
Subtask 26-17-00-810-161-E ** ON A/C NOT FOR ALL - replace the related lavatory smoke detector
AMM 26-17-15-000-001, AMM 26-17-15-000-008 and AMM 26-17-15-400-001, AMM 26-17-15-400-007.
C. If the test gives the maintenance message SMOKE DET LAV X CONTAMINATION (X = location of the related lavatory)
Subtask 26-17-00-810-161-F ** ON A/C NOT FOR ALL - replace the related lavatory smoke detector
AMM 26-17-15-000-802 and AMM 26-17-15-400-802 or AMM 26-17-15-000-808 and AMM 26-17-15-400-808.
C. If the test gives the maintenance message SMOKE DET LAV X CONTAMINATION (X = location of the related lavatory)
Subtask 26-17-00-710-083-A ** ON A/C NOT FOR ALL - replace the related lavatory smoke detector
AMM 26-17-15-000-802 and AMM 26-17-15-400-802 or AMM 26-17-15-000-808 and AMM 26-17-15-400-808 or AMM 26-17-15-000-809 and AMM 26-17-15-400-809.
D. Do the test as given in the Para. 3.
5. Close-upSubtask 26-17-00-860-062-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.