SDCU/SMOKE DET LOOP FAULT
TASK 26-17-00-810-807-A
SDCU/SMOKE DET LOOP FAULT
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-865-054-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-810-074-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-057-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:21 UTC
SDCU/SMOKE DET LOOP FAULT
1. Possible Causes
- electrical connectors
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 261602 | |
| AMM 26-16-15-000-001 | Removal of the Cargo-Compartment Smoke Detectors |
| AMM 26-16-15-400-001 | Installation of the Cargo-Compartment Smoke Detectors |
| ASM 261702 | |
| AMM 26-17-15-000-001 | Removal of the Lavatory Smoke Detector |
| AMM 26-17-15-400-001 | Installation of the Lavatory Smoke Detector |
| AMM 31-32-00-860-005 | Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page |
Subtask 26-17-00-865-054-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 26-17-00-710-064-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
B. Test
(1) Open the circuit breakers 11WQ and 12WQ.
(a) After 60 seconds, close the circuit breakers 11WQ and 12WQ.
(b) After one more minute, start the subsequent test.
(2) Get access to the MCDU/SDCU menu page AMM 31-32-00-860-005.
(a) Push the line key adjacent to the <ON GROUND FAULTS indication.
(b) The MCDU shows the fault message. If there is no fault, the MCDU shows NO FAILURE.
4. Fault Isolation(1) Open the circuit breakers 11WQ and 12WQ.
(a) After 60 seconds, close the circuit breakers 11WQ and 12WQ.
(b) After one more minute, start the subsequent test.
(2) Get access to the MCDU/SDCU menu page AMM 31-32-00-860-005.
(a) Push the line key adjacent to the <ON GROUND FAULTS indication.
(b) The MCDU shows the fault message. If there is no fault, the MCDU shows NO FAILURE.
Subtask 26-17-00-810-074-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-17-00-810-075-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message TEST OK, no other maintenance action is necessary.
Subtask 26-17-00-810-090-B ** ON A/C NOT FOR ALL C. If the test gives the status maintenance message SDCU and the maintenance message SDCU/SMOKE DET LOOP:
Subtask 26-17-00-710-065-A ** ON A/C NOT FOR ALL - Refer to the lavatory smoke detection schematic of the Description and Operation chapter AMM 261700 PB 001.
- Make sure that the electrical connectors at the SDCU (10WQ) and the related first connected smoke detectors are correctly installed ASM 261702.
- Read out the TROUBLE SHOOTING DATA (TSD).
NOTE: A is the number of SD's counted clockwise from the SDCU Channel 1.
B is the number of SD's counted counterclockwise from the SDCU Channel 2.
(a) If the TSD gives the complementary information xxxx xxxx xxxx xxxx 0/B: B is the number of SD's counted counterclockwise from the SDCU Channel 2.
- Replace the first SD AMM 26-17-15-000-001 AMM 26-17-15-400-001 counted clockwise from SDCU Channel 1.
- Do a check and repair the wiring if necessary between the SDCU (10WQ) and the related first lavatory smoke detector (XWQ):
SDCU (10WQ) connector AA/1A and the first smoke detector (XWQ) connector A/A
SDCU (10WQ) connector AA/1B and the first smoke detector (XWQ) connector A/B ASM 261702.
- Replace the first SD AMM 26-16-15-000-001 AMM 26-16-15-400-001 counted counterclockwise from SDCU Channel 2.
- Do a check and repair the wiring if necessary between the SDCU (10WQ) and the related first cargo smoke detector (XWH):
SDCU (10WQ) connector AB/1C and the first smoke detector (XWH) connector A/G
SDCU (10WQ) connector AB/1B and the first smoke detector (XWH) connector A/F ASM 261602.
D. Do the test given in Para. 3.
5. Close-upSubtask 26-17-00-860-057-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.