Pin Programming Configuration Fault
TASK 26-17-00-810-806-A
Pin Programming Configuration Fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-17-00-865-053-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-810-078-A ** ON A/C NOT FOR ALL
Subtask 26-17-00-860-058-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:39:08 UTC
Pin Programming Configuration Fault
1. Possible Causes
- PIN PROGRAMMING
- SDCU [10WQ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 261701 | |
| AMM 26-17-34-000-001 | Removal of the Smoke-Detection Control Unit (SDCU) |
| AMM 26-17-34-400-001 | Installation of the Smoke-Detection Control Unit (SDCU) |
| AMM 31-32-00-860-005 | Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page |
Subtask 26-17-00-865-053-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 26-17-00-710-066-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR COND/SDCU/CHAN1 | 11WQ | C06 |
| 122VU | AIR COND/SDCU/CHAN2 | 12WQ | T18 |
B. Test
(1) Open the circuit breakers 11WQ and 12WQ.
(a) After 60 seconds, close the circuit breakers 11WQ and 12WQ.
(b) After one more minute, start the subsequent test.
(2) Get access to the MCDU/SDCU menu page AMM 31-32-00-860-005.
(a) Push the line key adjacent to the <ON GROUND FAULTS indication.
(b) The MCDU shows the fault message. If there is no fault, the MCDU shows NO FAILURE.
4. Fault Isolation(1) Open the circuit breakers 11WQ and 12WQ.
(a) After 60 seconds, close the circuit breakers 11WQ and 12WQ.
(b) After one more minute, start the subsequent test.
(2) Get access to the MCDU/SDCU menu page AMM 31-32-00-860-005.
(a) Push the line key adjacent to the <ON GROUND FAULTS indication.
(b) The MCDU shows the fault message. If there is no fault, the MCDU shows NO FAILURE.
Subtask 26-17-00-810-078-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-17-00-810-079-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message TEST OK, no other maintenance action is necessary.
Subtask 26-17-00-810-080-A ** ON A/C NOT FOR ALL C. If the test gives the maintenance message WRG:PIN PROG:
Subtask 26-17-00-810-081-A ** ON A/C NOT FOR ALL - Do a check and repair of the PIN PROGRAMMING at the pin B/8D of the SDCU (10WQ) ASM 261701.
- Replace the SDCU [10WQ] AMM 26-17-34-000-001 and AMM 26-17-34-400-001.
D. Do the test given in Para. 3.
5. Close-upSubtask 26-17-00-860-058-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.