Lavatory Smoke Detection Fault


TASK 26-17-00-810-801-A
Lavatory Smoke Detection Fault


1. Possible Causes
  • lavatory smoke detector
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-17-00-710-001
Operational Test of the Lavatory Smoke-Detection System
AMM 26-17-15-000-001
Removal of the Lavatory Smoke Detector
AMM 26-17-15-400-001
Installation of the Lavatory Smoke Detector
3. Fault Confirmation
Subtask 26-17-00-865-050-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/SDCU/CHAN111WQC06
122VUAIR COND/SDCU/CHAN212WQT18
Subtask 26-17-00-710-050-A ** ON A/C NOT FOR ALL
B. Test
   (1) Open the circuit breakers 11WQ and 12WQ.
     (a) After 60 seconds, close the circuit breakers 11WQ and 12WQ.
     (b) After one more minute, start the subsequent test.
   (2) Do the operational test of the lavatory smoke-detection system AMM 26-17-00-710-001.
4. Fault Isolation
Subtask 26-17-00-810-062-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-17-00-810-063-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message TEST OK, no other maintenance action is necessary.
Subtask 26-17-00-810-050-A ** ON A/C NOT FOR ALL
C. If the test gives the maintenance message SMOKE DET LAV X (YWQ):
NOTE: X/Y shows the related lavatory location.
Subtask 26-17-00-710-051-A ** ON A/C NOT FOR ALL
D. Do the test as given in the Para. 3.
5. Close-up
Subtask 26-17-00-860-050-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.