No data from neither SDF channel
TASK 26-16-00-810-829-A
No data from neither SDF channel
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 26-16-00-710-103-A ** ON A/C NOT FOR ALL
Subtask 26-16-00-810-127-A ** ON A/C NOT FOR ALL
Subtask 26-16-00-860-077-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:19 UTC
No data from neither SDF channel
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 237301 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 26-10-00-740-801 | BITE Test of the Smoke Detection Function - System Test |
Subtask 26-16-00-710-103-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the BITE the test of the smoke detection function - system test AMM 26-10-00-740-801.
4. Fault Isolation(1) Do the BITE the test of the smoke detection function - system test AMM 26-10-00-740-801.
Subtask 26-16-00-810-127-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
Subtask 26-16-00-810-128-A ** ON A/C NOT FOR ALL - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message
CIDS(102RH)-SDF2 BUS/ CIDS(101RH)-SDF1 or SDF1(101RH)-DIR2(102RH):
(1) Replace DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(2) If the fault continues:
Subtask 26-16-00-810-129-A ** ON A/C NOT FOR ALL CIDS(102RH)-SDF2 BUS/ CIDS(101RH)-SDF1 or SDF1(101RH)-DIR2(102RH):
(1) Replace DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(2) If the fault continues:
- Do a check and repair the wiring between connector AA of DIR-CIDS, 1 [101RH] pin 11J and 11K to connector AA of DIR-CIDS, 2 [102RH] pin 15C and 15H ASM 237301.
C. If the test gives the maintenance message
CIDS(101RH)-SDF1 BUS/ CIDS(102RH)-SDF2 or SDF2(102RH)-DIR1(101RH):
(1) Replace DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(2) If the fault continues:
Subtask 26-16-00-710-104-A ** ON A/C NOT FOR ALL CIDS(101RH)-SDF1 BUS/ CIDS(102RH)-SDF2 or SDF2(102RH)-DIR1(101RH):
(1) Replace DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
(2) If the fault continues:
- Do a check and repair the wiring between connector AA of DIR-CIDS, 2 [102RH] pin 11J and 11K to connector AA of DIR-CIDS, 1 [101RH] pin 15C and 15H ASM 237301.
D. Do the test given in Para. 3.
5. Close-upSubtask 26-16-00-860-077-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(1) Make sure that the work area is clean and clear of tools and other items.