W DOC AIRBUS | TSM A320F

No Smoke Warning on OVHD Panel and/or ECAM


TASK 26-16-00-810-818-A
No Smoke Warning on OVHD Panel and/or ECAM


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 26-10-00-740-802
Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF)
AMM 31-53-34-000-001
Removal of the Flight Warning Computer (FWC)
AMM 31-53-34-400-001
Installation of the Flight Warning Computer (FWC)
3. Fault Confirmation
Subtask 26-16-00-865-064-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/CIDS/SDF/DIR2 ESS18WHC06
49VUAIR COND/CIDS/SDF/DIR1 ESS15WHC05
122VUAIR COND/CIDS/SDF/DIR NORM/214WHT18
122VUAIR COND/CIDS/SDF/DIR NORM/117WHT17
Subtask 26-16-00-710-085-A ** ON A/C NOT FOR ALL
B. Test
   (1) Open the circuit breakers 14WH, 15WH, 17WH and 18WH, wait for approximately 10 seconds and close them again, wait for a minimum of 30 seconds before you start the test.
   (2) After a minimum time of 30 seconds, do the Ground Scanning of the Cabin Intercommunication Data-System (CIDS) - Smoke Detection Function (SDF) AMM 26-10-00-740-802.
4. Fault Isolation
Subtask 26-16-00-810-098-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-16-00-810-099-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message
SMK IND (11WH)/ FWC1/2 (1WW1/2)/ CIDS DIR1 (101RH):
   (1) If the indicator light (11WH) did not come on:
  • Replace the related lamp.
     (a) If the fault continues:
  • Do a check and repair the aircraft wiring if necessary between the DIR-CIDS, 1 [101RH] and the related lamp.
       1 If the fault continues:
   (2) If the ECAM warning did not come on:
     (a) If the fault continues:
Subtask 26-16-00-810-100-A ** ON A/C NOT FOR ALL
C. If the test gives the maintenance message
SMK IND (11WH)/ FWC1/2 (1WW1/2)/ CIDS DIR2 (102RH):
   (1) If the indicator light (11WH) did not come on:
  • Replace the related lamp.
     (a) If the fault continues:
  • Do a check and repair the aircraft wiring if necessary between the DIR-CIDS, 2 [102RH] and the related lamp.
       1 If the fault continues:
   (2) If the ECAM warning did not come on:
     (a) If the fault continues:
Subtask 26-16-00-710-086-A ** ON A/C NOT FOR ALL
D. Do the test as given in the Para. 3.
5. Close-up
Subtask 26-16-00-860-067-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:27:19 UTC