W DOC AIRBUS | TSM A320F

Smoke Warnings without Smoke


TASK 26-15-00-810-803-A
Smoke Warnings without Smoke


1. Possible Causes
  • DET-SMOKE, AVNCS COMPT [1WA]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-15-15-000-001
Removal of the Smoke Detector - Avionics Compartment
AMM 26-15-15-400-001
Installation of the Smoke Detector - Avionics Compartment
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
3. Fault Confirmation
Subtask 26-15-00-710-054-A
A. Test
Not applicable, the fault is evident.
4. Fault Isolation
Subtask 26-15-00-810-052-A
A. If smoke warnings come into view in the cockpit without smoke:
   (1) Do a reset of the AEVC (10HQ):
  • open the circuit breaker 5HQ for some seconds before you close it.
     (a) If the fault continues:
       1 Reset of the FWC1 and FWC2
NOTE: Open the circuit breakers for some seconds before you close them.
         a Open this(these) circuit breaker(s):
  • 2WW
  • 3WW
         b Close this(these) circuit breaker(s):
[Rev.8 from Aug 2018] 2026.04.04 04:27:18 UTC