Failure of the APU FDU


TASK 26-13-00-810-813-A
Failure of the APU FDU


1. Possible Causes
  • FDU-APU [13WG]
  • WIRING
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-13-00-710-002
BITE Test of the APU Fire and Overheat Detection System
ASM 261301
AMM 26-13-34-000-001
Removal of the APU Fire-Detection Unit (FDU)
AMM 26-13-34-400-001
Installation of the APU Fire-Detection Unit (FDU)
3. Fault Confirmation
Subtask 26-13-00-740-050-A
A. Do the Bite test of the APU fire and overheat detection system AMM 26-13-00-710-002.
4. Fault Isolation
Subtask 26-13-00-810-075-A
A. If the Bite test gives a maintenance message different from FDU APU:
  • Do the trouble-shooting procedure related to the maintenance message.
Subtask 26-13-00-810-076-A
B. If the Bite test gives the maintenance message FDU APU:
Subtask 26-13-00-740-051-A
C. Do the test given in Para. 3.
Subtask 26-13-00-810-077-A
D. If the fault continues:
   (1) Do a check and repair the WIRING between:
     (a) FDU-APU [13WG] connector A pin A and CB (1WG),
     (b) FDU-APU [13WG] connector B pin A and CB (2WG),
     (c) FDU-APU [13WG] connector A pin B and GND,
     (d) FDU-APU [13WG] connector B pin N and GND,
     (e) FDU-APU [13WG] connector B pin B and GND.
ASM 261301
5. Close-up
Subtask 26-13-00-860-055-A
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.