W DOC AIRBUS | TSM A320F

LGCIU Signal Mismatch


TASK 26-13-00-810-805-A
LGCIU Signal Mismatch


1. Possible Causes
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-13-00-710-002
BITE Test of the APU Fire and Overheat Detection System
AMM 32-69-00-740-001
BITE Check of Landing-Gear Control Interface-Unit (LGCIU) With Use of MCDU to Ensure that Continuous BITE is Operative
3. Fault Confirmation
Subtask 26-13-00-710-058-A
A. Do the BITE test of the APU fire and overheat detection system AMM 26-13-00-710-002.
4. Fault Isolation
Subtask 26-13-00-810-067-A
A. If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 26-13-00-810-062-A
B. If the test gives the maintenance message CHECK FDU APU LGCIU INTFC:
   (1) If the test gives a different maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) If the fault continues:
  • do a check and repair the aircraft wiring if necessary between the:
    FDU (13WG) connector A/D and LGCIU 1 (5GA1) connector AB/2B,
    FDU (13WG) connector B/D and LGCIU 2 (5GA2) connector AB/2B.
Subtask 26-13-00-710-059-A
C. Do the test as given in the Para. 3.A.
5. Close-up
Subtask 26-13-00-860-054-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:27:17 UTC