APU Detection Loop A and/or Loop B Inop Signal Output
TASK 26-13-00-810-803-A
APU Detection Loop A and/or Loop B Inop Signal Output
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 26-13-00-710-086-A
Subtask 26-13-00-810-065-A
Subtask 26-13-00-860-052-A
[Rev.8 from Aug 2018]
2026.04.04 04:27:17 UTC
APU Detection Loop A and/or Loop B Inop Signal Output
1. Possible Causes
- FDU-APU [13WG]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 26-13-00-710-002 | BITE Test of the APU Fire and Overheat Detection System |
| ASM 261301 | |
| AMM 26-13-34-000-001 | Removal of the APU Fire-Detection Unit (FDU) |
| AMM 26-13-34-400-001 | Installation of the APU Fire-Detection Unit (FDU) |
| AWM 315218 |
Subtask 26-13-00-710-086-A
A. If the Electric Ground Supply energizes the aircraft:
(2) EXT PWR to "ON"
(3) BAT 1+2 to "ON"
Subtask 26-13-00-710-088-A - Operate the switches only in this order:
(2) EXT PWR to "ON"
(3) BAT 1+2 to "ON"
- Do the BITE test of the APU fire and overheat detection system AMM 26-13-00-710-002.
B. If the APU energizes the aircraft:
4. Fault Isolation- Do the BITE Test of the APU Fire and Overheat Detection with the CFDS' after the APU starts AMM 26-13-00-710-002.
NOTE: If FWC and FDU are connected and all other systems operate satisfactorily, the message "Test OK" is displayed. The "CHECK FDU APU LOOP A/ or B WARN CKT" will be cleared next "Ground/Flight" transition.
Subtask 26-13-00-810-065-A
A. If the test gives a different maintenance message:
Subtask 26-13-00-810-081-A - Do the trouble shooting procedure related to the maintenance message.
B. If the test gives the maintenance message CHECK FDU APU LOOP A WARN CKT:
Subtask 26-13-00-710-087-A - replace the FDU-APU [13WG] AMM 26-13-34-000-001 and AMM 26-13-34-400-001.
- do a check and repair of the wiring between
FDU 13WG-A/M and the first terminal block
ASM 261301 and AWM 315218.
C. Do the test as given in the Para. 3.A.
Subtask 26-13-00-810-082-A D. If the test gives the maintenance message CHECK FDU APU LOOP B WARN CKT:
Subtask 26-13-00-710-055-A - replace the FDU-APU [13WG] AMM 26-13-34-000-001 and AMM 26-13-34-400-001.
- do a check and repair of the wiring between
FDU 13WG-B/L and the first terminal block
ASM 261301 and AWM 315218.
E. Do the test as given in the Para. 3.A.
5. Close-upSubtask 26-13-00-860-052-A
A. Put the aircraft back to its initial configuration.