Loss of Detection by Engine-1 Loop-A AGB


TASK 26-12-00-810-852-A
Loss of Detection by Engine-1 Loop-A AGB


1. Possible Causes
  • DET-FIRE, CORE AGB LOOP A [4002WD1]
  • wiring
  • fire-electrical-harness loop-A
  • FDU-ENG1 [2WD1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 26-12-00-810-851-A
Loss of Detection by Engine-1 Loop-A Core
AMM 26-12-00-200-802
Visual Inspection of the Engine Fire Detection System
AMM 26-12-00-710-002
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
ASM 261201
AWM 261205
AMM 26-12-17-000-802
Removal of the Forward Fire/Overheat Detector
AMM 26-12-17-400-802
Installation of the Forward Fire/Overheat Detector
AMM 26-12-34-000-001
Removal of the Engine Fire-Detection Unit (FDU)
AMM 26-12-34-400-001
Installation of the Engine Fire-Detection Unit (FDU)
AMM 26-12-61-000-802
Removal of the Loop-A Fire Harness and Electrical Rail Assembly
AMM 26-12-61-400-802
Installation of the Loop-A Fire Harness and Electrical Rail Assembly
AWM 715175
3. Fault Confirmation
Subtask 26-12-00-710-154-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the engine fire and overheat detection from the Multipurpose Control and Display Unit (MCDU) AMM 26-12-00-710-002.
4. Fault Isolation
Subtask 26-12-00-810-107-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
  • If, on the PFR, the CHECK ENG1 FIRE LOOP A AGB fault message is shown, do not do the troubleshooting that follows but go to (Ref. TSM TASK 26-12-00-810-851).
  • Do a visual inspection of the core-AGB loop-A fire-detector (4002WD1) AMM 26-12-00-200-802.
   (1) If the fire detector is damaged:
   (2) If there is no visual damage:
  • Disconnect the electrical harness from the core-AGB loop-A fire-detector (4002WD1).
  • On the responder of core-AGB loop-A fire-detector (4002WD1), make sure that the resistance value is between 3078 ohms and 3402 ohms between pins A and C, ASM 261201.
     (a) If the resistance values are out of the specified limits:
     (b) If the resistance values are in the specified limits:
  • Do a check of the wiring between the pins A and C of the core-AGB loop-A fire-detector (4002WD1) and the first terminal-block, AWM 261205 and AWM 715175.
       1 If the wiring is not correct:
  • Do a check of the wiring between the first terminal-block and the fire-electrical-harness loop-A AWM 261205 and AWM 715175.
         a If the wiring is not correct:
  • Repair it.
  • Connect the electrical harness to the core-AGB loop-A fire-detector (4002WD1).
         b If the wiring is correct:
       2 If the wiring is correct:
Subtask 26-12-00-710-155-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.