W DOC AIRBUS | TSM A320F

Loss of the ENG 1 Fire-Test Loop A Input


TASK 26-12-00-810-844-A
Loss of the ENG 1 Fire-Test Loop A Input


1. Possible Causes
  • FDU-ENG1 [2WD1]
  • wiring
  • ENG/APU FIRE PNL [1WD]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-12-00-710-001
Operational Check of Loop/Squib
AMM 26-12-00-710-002
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
ASM 261202
AMM 26-12-12-000-001
Removal of the ENG/APU Fire Panel
AMM 26-12-12-400-001
Installation of the ENG/APU Fire Panel
AMM 26-12-34-000-001
Removal of the Engine Fire-Detection Unit (FDU)
AMM 26-12-34-400-001
Installation of the Engine Fire-Detection Unit (FDU)
3. Fault Confirmation
Subtask 26-12-00-710-138-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the engine fire and overheat detection from the Multipurpose Control and Display Unit (MCDU) AMM 26-12-00-710-002.
Subtask 26-12-00-710-138-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational check of loop/squib AMM 26-12-00-710-001.
4. Fault Isolation
Subtask 26-12-00-810-097-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CHECK FDU ENG1 FIRE TEST PB SW/FDU ENG1:
   (1) If the fault continues:
  • do a check of the wiring between the ENG/APU fire panel 1WD pin A/N and the engine 1 FDU pin A/C and repair if necessary ASM 261202.
   (2) If the fault continues:
  • do a check and repair the wiring from the ENG/APU fire panel 1WD pin A/M to the circuit breaker 7WD1 ASM 261202.
   (3) If the fault continues:
Subtask 26-12-00-810-097-B ** ON A/C NOT FOR ALL
A. If during the test, the legend of the ENG1 FIRE pushbutton switch is not fully on (four rows not fully on):
   (1) If the fault continues:
  • Do a check of the wiring between ENG/APU fire panel 1WD pin A/N and engine 1 FDU pin A/C and repair if necessary, ASM 261202.
   (2) If the fault continues:
  • Do a check and repair the wiring between ENG/APU fire panel 1WD pin A/M and circuit breaker 7WD1, ASM 261202.
   (3) If the fault continues:
Subtask 26-12-00-710-139-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:11 UTC