W DOC AIRBUS | TSM A320F

Loss of the FDU Pin-Programming


TASK 26-12-00-810-837-A
Loss of the FDU Pin-Programming


1. Possible Causes
  • FDU-APU [13WG]
  • FDU-ENG1 [2WD1]
  • FDU-ENG2 [2WD2]
  • wiring of the IDENTIFICATION discretes of the APU FDU
  • wiring of the IDENTIFICATION discretes of the engine 1 FDU and the engine 2 FDU
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-12-00-710-002
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
ASM 261201
AMM 26-12-34-000-001
Removal of the Engine Fire-Detection Unit (FDU)
AMM 26-12-34-400-001
Installation of the Engine Fire-Detection Unit (FDU)
ASM 261301
AMM 26-13-34-000-001
Removal of the APU Fire-Detection Unit (FDU)
AMM 26-13-34-400-001
Installation of the APU Fire-Detection Unit (FDU)
3. Fault Confirmation
Subtask 26-12-00-710-120-A
A. Test
   (1) Do the operational test of the engine fire and overheat detection from the Multipurpose Control and Display Unit (MCDU) AMM 26-12-00-710-002.
4. Fault Isolation
Subtask 26-12-00-810-090-A
A. If the test gives the maintenance message CHECK FDU PIN PROG:
   (1) If the fault continues:
  • do a check and repair the wiring of the IDENTIFICATION discretes of the APU FDU from pins A/N and A/L to the ground point ASM 261301
  • do a check and repair the wiring of the IDENTIFICATION discretes of the engine 1 FDU and the engine 2 FDU from pins A/L to the ground point ASM 261201.
Subtask 26-12-00-710-121-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:11 UTC