Loss of the FIRE TEST (LOOP A) Discrete Input from the Engine 1 FDU


TASK 26-12-00-810-827-A
Loss of the FIRE TEST (LOOP A) Discrete Input from the Engine 1 FDU


1. Possible Causes
  • ENG/APU FIRE PNL [1WD]
  • wiring of the 28VDC signal from the circuit breaker (7WD1) to the ENG/APU FIRE panel (1WD)
  • wiring of the FIRE TEST (LOOP A) discrete from the engine 1 FDU (2WD1) to the ENG/APU FIRE panel (1WD)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-12-00-710-001
Operational Check of Loop/Squib
ASM 261202
AMM 26-12-12-000-001
Removal of the ENG/APU Fire Panel
AMM 26-12-12-400-001
Installation of the ENG/APU Fire Panel
3. Fault Confirmation
Subtask 26-12-00-710-100-A
A. Test
   (1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
4. Fault Isolation
Subtask 26-12-00-810-080-A
A. If the ENG 1 FIRE indication does not come into view on the upper ECAM DU and if the FIRE legend of the ENG 1 annunciator does not come on on the ENG panel 115VU:
  • do a check to see if the DISCH legend of the ENG 1/AGENT 1 pushbutton switch on the ENG/APU FIRE panel (1WD) comes on during the fire test.
   (1) If the DISCH legend does not come on:
     (a) If the fault continues:
  • do a check and repair the wiring of the 28VDC signal from the circuit breaker (7WD1) to the ENG/APU FIRE panel (1WD), pin A/M ASM 261202.
   (2) If the DISCH legend comes on:
     (a) If the fault continues:
  • do a check and repair the wiring of the FIRE TEST (LOOP A) discrete from the engine 1 FDU (2WD1) to the ENG/APU FIRE panel (1WD) ASM 261202.
Subtask 26-12-00-710-101-A
B. Do the test given in Para. 3.