W DOC AIRBUS | TSM A320F

Loss of the First and Third Rows of the Legend of the ENG 1 FIRE Pushbutton Switch and the FIRE Legend of the ENG/1 FIRE/FAULT Annunciator


TASK 26-12-00-810-819-A
Loss of the First and Third Rows of the Legend of the ENG 1 FIRE Pushbutton Switch and the FIRE Legend of the ENG/1 FIRE/FAULT Annunciator


1. Possible Causes
  • BOARD-ANN LT TEST & INTFC [5LP]
  • wiring of the annunciator light test and interface board (5LP)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-12-00-710-001
Operational Check of Loop/Squib
ASM 261201
AMM 33-14-33-000-001
Removal of the Annunciator-Light Test and Interface-Board
AMM 33-14-33-400-001
Installation of the Annunciator-Light Test and Interface-Board
3. Fault Confirmation
Subtask 26-12-00-710-084-A
A. Test
   (1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
4. Fault Isolation
Subtask 26-12-00-810-068-A
A. If during the test, the first and third rows of the legend of the ENG 1 FIRE pushbutton switch and the FIRE legend of the ENG/1 FIRE/FAULT annunciator do not come on:
   (1) If the fault continues:
  • do a check and repair the wiring of the annunciator light test and interface board (5LP), from pin A/33 to the first terminal block ASM 261201.
Subtask 26-12-00-710-085-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:09 UTC