W DOC AIRBUS | TSM A320F

Loss of the FIRE Legend of ENG/1 FIRE/FAULT Annunciator


TASK 26-12-00-810-817-A
Loss of the FIRE Legend of ENG/1 FIRE/FAULT Annunciator


1. Possible Causes
  • BOARD-ANN LT TEST & INTFC [5LP]
  • wiring of the annunciator light test and interface board (5LP)
  • ENG/1 FIRE/FAULT annunciator (5KS1)
  • wiring of the ENG/1 FIRE/FAULT annunciator (5KS1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 26-12-00-710-001
Operational Check of Loop/Squib
ASM 261201
AMM 33-14-33-000-001
Removal of the Annunciator-Light Test and Interface-Board
AMM 33-14-33-400-001
Installation of the Annunciator-Light Test and Interface-Board
3. Fault Confirmation
Subtask 26-12-00-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
122VULIGHTING/TST/BOARD/SPLY30LPX06
Subtask 26-12-00-710-080-A
B. Test
   (1) Do the operational test of the engine fire and overheat detection (loop/squib) AMM 26-12-00-710-001.
4. Fault Isolation
Subtask 26-12-00-810-066-A
A. If during the test, the FIRE legend of the ENG/1 FIRE/FAULT annunciator does not come on:
  • on the panel 25VU, set the ANN LT switch to TEST and do a check to see if the FIRE legend of the ENG/1 FIRE/FAULT annunciator comes on.
   (1) If it comes on:
     (a) If the fault continues:
  • do a check and repair the wiring of the annunciator light test and interface board (5LP), from pin A/38 to the first terminal block and from pin A/39 to pin A/32 ASM 261201.
     (b) If it does not come on:
  • replace the ENG/1 FIRE/FAULT annunciator (5KS1).
       1 If the fault continues:
  • do a check and repair the wiring of the ENG/1 FIRE/FAULT annunciator (5KS1), from pin A/9 to the first terminal block and from pin A/7 to the pin A/37 of the annunciator light test and interface board (5LP) ASM 261201.
Subtask 26-12-00-710-081-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 26-12-00-860-054-A
A. Put the aircraft back to its initial configuration.
   (1) On the panel 25VU, set the ANN LT switch to BRT.
[Rev.8 from Aug 2018] 2026.04.04 04:27:09 UTC