Fault of the Escape Slide Light at the RH Door 3 (Light Failure)
TASK 25-62-00-810-818-A
Fault of the Escape Slide Light at the RH Door 3 (Light Failure)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 25-62-00-710-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-62-00-810-092-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-860-059-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:04 UTC
Fault of the Escape Slide Light at the RH Door 3 (Light Failure)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 25-62-47-000-001 | Removal of the Escape Slide Enclosure |
| AMM 25-62-47-400-001 | Installation of the Escape Slide Enclosure |
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| ASM 335102 | |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
Subtask 25-62-00-710-077-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-62-00-810-092-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 25-62-00-810-077-A ** ON A/C NOT FOR ALL B. If the test gives the maintenance message ESCAPE SLIDE LT / EPSU (12WL) EXT R:
Subtask 25-62-00-710-092-A ** ON A/C NOT FOR ALL - Replace the ESCAPE SLIDE, DOOR 3, RH ESCAPE SLIDE FOR DOOR 3RH [7773MM] AMM 25-62-47-000-001 and AMM 25-62-47-400-001.
- Replace the EPSU [12WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- Do a check and repair the aircraft wiring from the EPSU [12WL] to the escape slide connector 6712VC ASM 335102.
C. Do the test given in Para. 3.
5. Close-upSubtask 25-62-00-860-059-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.