W DOC AIRBUS | TSM A320F

Fault of the Escape Slide Light at the RH Door 3 (Light Failure)


TASK 25-62-00-810-818-A
Fault of the Escape Slide Light at the RH Door 3 (Light Failure)


1. Possible Causes
  • ESCAPE SLIDE FOR DOOR 3RH [7773MM]
  • EPSU [12WL]
  • aircraft wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 25-62-47-000-001
Removal of the Escape Slide Enclosure
AMM 25-62-47-400-001
Installation of the Escape Slide Enclosure
AMM 33-51-00-710-001
Operational Test of the Emergency Lights
ASM 335102
AMM 33-51-38-000-001
Removal of the Emergency Power-Supply Unit (EPSU)
AMM 33-51-38-400-001
Installation of the Emergency Power-Supply Unit (EPSU)
3. Fault Confirmation
Subtask 25-62-00-710-077-A ** ON A/C NOT FOR ALL
A. Do the operational test of the emergency lighting system AMM 33-51-00-710-001.
4. Fault Isolation
Subtask 25-62-00-810-092-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 25-62-00-810-077-A ** ON A/C NOT FOR ALL
B. If the test gives the maintenance message ESCAPE SLIDE LT / EPSU (12WL) EXT R:
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check and repair the aircraft wiring from the EPSU [12WL] to the escape slide connector 6712VC ASM 335102.
Subtask 25-62-00-710-092-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.
5. Close-up
Subtask 25-62-00-860-059-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:27:04 UTC