Fault of the Escape Slide Light at the LH Door 3 (Light Failure)
TASK 25-62-00-810-817-A
Fault of the Escape Slide Light at the LH Door 3 (Light Failure)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 25-62-00-710-076-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-62-00-810-091-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-860-058-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:04 UTC
Fault of the Escape Slide Light at the LH Door 3 (Light Failure)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 25-62-47-000-001 | Removal of the Escape Slide Enclosure |
| AMM 25-62-47-400-001 | Installation of the Escape Slide Enclosure |
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| ASM 335102 | |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
Subtask 25-62-00-710-076-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-62-00-810-091-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 25-62-00-810-076-A ** ON A/C NOT FOR ALL B. If the test gives the maintenance message ESCAPE SLIDE LT / EPSU (11WL) EXT L:
Subtask 25-62-00-710-091-A ** ON A/C NOT FOR ALL - Replace the ESCAPE SLIDE, DOOR 3, LH ESCAPE SLIDE FOR DOOR 3LH [7772MM] AMM 25-62-47-000-001 and AMM 25-62-47-400-001.
- Replace the EPSU [11WL] AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- Do a check and repair the aircraft wiring from the EPSU [11WL] to the escape slide connector 6713VC ASM 335102.
C. Do the test given in Para. 3.
5. Close-upSubtask 25-62-00-860-058-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.