Fault of the Escape Slide Light at the RH Door 2 (Light Failure)
TASK 25-62-00-810-816-A
Fault of the Escape Slide Light at the RH Door 2 (Light Failure)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 25-62-00-710-075-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-62-00-810-090-A ** ON A/C NOT FOR ALL
Subtask 25-62-00-860-057-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:04 UTC
Fault of the Escape Slide Light at the RH Door 2 (Light Failure)
1. Possible Causes
- ESCAPE SLIDE FOR DOOR 2RH [7771MM]
- 14WL
- aircraft wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 25-62-47-000-001 | Removal of the Escape Slide Enclosure |
| AMM 25-62-47-400-001 | Installation of the Escape Slide Enclosure |
| AMM 33-51-00-710-001 | Operational Test of the Emergency Lights |
| ASM 335102 | |
| AMM 33-51-38-000-001 | Removal of the Emergency Power-Supply Unit (EPSU) |
| AMM 33-51-38-400-001 | Installation of the Emergency Power-Supply Unit (EPSU) |
Subtask 25-62-00-710-075-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-62-00-810-090-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 25-62-00-810-075-A ** ON A/C NOT FOR ALL B. If the test gives the maintenance message ESCAPE SLIDE LT / EPSU (14WL) MID R:
Subtask 25-62-00-710-090-A ** ON A/C NOT FOR ALL - Replace the ESCAPE SLIDE, DOOR 2, RH ESCAPE SLIDE FOR DOOR 2RH [7771MM] AMM 25-62-47-000-001 and AMM 25-62-47-400-001.
- Replace the EMERGENCY POWER SUPPLY UNIT 14WL AMM 33-51-38-000-001 and AMM 33-51-38-400-001.
- Do a check and repair the aircraft wiring from the EMERGENCY POWER SUPPLY UNIT 14WL to the escape slide connector 1870VC ASM 335102.
C. Do the test given in Para. 3.
5. Close-upSubtask 25-62-00-860-057-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.