EQUIP/FURNIS - DOOR AREA HEATING - DOOR 1 RH - All heated floor panels are INOP
TASK 25-27-00-810-810-A
EQUIP/FURNIS - DOOR AREA HEATING - DOOR 1 RH - All heated floor panels are INOP
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 25-27-00-740-072-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-27-00-810-073-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:01 UTC
EQUIP/FURNIS - DOOR AREA HEATING - DOOR 1 RH - All heated floor panels are INOP
1. Possible Causes
- C/B-DR AREA HTG PNLS-DOOR1-FPH- or C/B-DR AREA HTG PNLS-DR1-FPH-RH [52DS]
- CTL UNIT-DOOR AREA HEATING [66DS]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 25-27-00-740-001 | Bite Test of the Heated Floor Panel System |
| ASM 252703 | |
| AMM 25-27-34-000-002 | Removal of the Control Unit 60DS, 66DS |
| AMM 25-27-34-400-002 | Installation of the Control Unit 60DS, 66DS |
Subtask 25-27-00-740-072-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-27-00-810-073-A ** ON A/C NOT FOR ALL
A. If the test indicators on the control unit 66DS do not come on:
Subtask 25-27-00-740-073-A ** ON A/C NOT FOR ALL - Do a check for 115 VAC on the electrical connector 66DS-B, pin A1.
- Do a check of the aircraft wiring between the related electrical connector 66DS-B, pin A1 and the circuit breaker 52DS ASM 252703.
- Replace the circuit breaker C/B-DR AREA HTG PNLS-DOOR1-FPH- or C/B-DR AREA HTG PNLS-DR1-FPH-RH [52DS] .
- Repair the aircraft wiring ASM 252703.
- Do a check for 28 VDC on the electrical connector 66DS-A, pin 16.
- Repair the aircraft wiring between the electrical connector 66DS-A, pin 16 and the associated terminal block ASM 252703.
- Replace the CTL UNIT-DOOR AREA HEATING [66DS] AMM 25-27-34-000-002 and AMM 25-27-34-400-002.
B. Do the test given in Para. 3.A.