EQUIP/FURNIS - DOOR AREA HEATING - One heated floor panel is INOP
TASK 25-27-00-810-807-A
EQUIP/FURNIS - DOOR AREA HEATING - One heated floor panel is INOP
1. Possible Causes
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Fault Confirmation
Subtask 25-27-00-740-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-27-00-810-068-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:01 UTC
EQUIP/FURNIS - DOOR AREA HEATING - One heated floor panel is INOP
1. Possible Causes
- control unit
- heated floor panel
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | MULTIMETER - STANDARD |
| REFERENCE | DESIGNATION |
|---|---|
| AMM 25-27-00-740-001 | Bite Test of the Heated Floor Panel System |
| ASM 252701 | |
| ASM 252702 | |
| ASM 252703 | |
| AMM 25-27-34-000-002 | Removal of the Control Unit 60DS, 66DS |
| AMM 25-27-34-400-002 | Installation of the Control Unit 60DS, 66DS |
| AMM 25-27-51-000-002 | Removal of the Heated Floor Panel 31DS , 33DS |
| AMM 25-27-51-400-002 | Installation of the Heated Floor Panel 31DS , 33DS |
Subtask 25-27-00-740-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-27-00-810-068-A ** ON A/C NOT FOR ALL
A. Fault Isolation for Control Units 4DS and 14DS
If one test indicator on the related control unit does not come on:
Subtask 25-27-00-810-076-A ** ON A/C NOT FOR ALL If one test indicator on the related control unit does not come on:
- Do a check of the related fuse.
- Do a check of the aircraft wiring for a short circuit between the related control unit and the inoperative heated floor panel, ASM 252701 or ASM 252702. Use a MULTIMETER - STANDARD.
- Repair the aircraft wiring, ASM 252701 or ASM 252702.
- Replace the fuse.
- Replace the related control unit , AMM 25-27-34-000-002 and AMM 25-27-34-400-002.
- Replace the fuse.
- Replace the related heated floor panel , AMM 25-27-51-000-002 and AMM 25-27-51-400-002.
- Replace the fuse.
- Do a check of the aircraft wiring between the related control unit and the inoperative heated floor panel, ASM 252701 or ASM 252702. Use a MULTIMETER - STANDARD.
- Interchange the connector and do the test given in Para. 3.
- Replace the related control unit , AMM 25-27-34-000-002 and AMM 25-27-34-400-002.
- Replace the related heated floor panel , AMM 25-27-51-000-002 and AMM 25-27-51-400-002.
- Repair the aircraft wiring, ASM 252703.
B. Fault Isolation for Control Units 60DS and 66DS
If one test indicator on the related control unit does not come on:
Subtask 25-27-00-740-063-A ** ON A/C NOT FOR ALL If one test indicator on the related control unit does not come on:
- Do a check of the related fuse.
- Do a check of the aircraft wiring for a short circuit between the related control unit and the inoperative heated floor panel, ASM 252703. Use a MULTIMETER - STANDARD.
- Repair the aircraft wiring, ASM 252703.
- Replace the fuse.
- Replace the related control unit , AMM 25-27-34-000-002 and AMM 25-27-34-400-002.
- Replace the fuse.
- Replace the related heated floor panel , AMM 25-27-51-000-002 and AMM 25-27-51-400-002.
- Replace the fuse.
- Do a check of the aircraft wiring between the related control unit and the inoperative heated floor panel, ASM 252703. Use a MULTIMETER - STANDARD.
- Interchange the connectors A and B and do the test given in Para. 3.
- Replace the related control unit , AMM 25-27-34-000-002 and AMM 25-27-34-400-002.
- Replace the related heated floor panel , AMM 25-27-51-000-002 and AMM 25-27-51-400-002.
- Repair the aircraft wiring, ASM 252703.
C. Do the test given in para. 3.A.