EQUIP/FURNIS - DOOR AREA HEATING - One heated floor panel is INOP


TASK 25-27-00-810-807-A
EQUIP/FURNIS - DOOR AREA HEATING - One heated floor panel is INOP


1. Possible Causes
  • control unit
  • heated floor panel
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
MULTIMETER - STANDARD
 B. Referenced Information
REFERENCE
DESIGNATION
AMM 25-27-00-740-001
Bite Test of the Heated Floor Panel System
ASM 252701
ASM 252702
ASM 252703
AMM 25-27-34-000-002
Removal of the Control Unit 60DS, 66DS
AMM 25-27-34-400-002
Installation of the Control Unit 60DS, 66DS
AMM 25-27-51-000-002
Removal of the Heated Floor Panel 31DS , 33DS
AMM 25-27-51-400-002
Installation of the Heated Floor Panel 31DS , 33DS
3. Fault Confirmation
Subtask 25-27-00-740-062-A ** ON A/C NOT FOR ALL
A. Do the Bite Test of the Heated Floor Panel System AMM 25-27-00-740-001.
4. Fault Isolation
Subtask 25-27-00-810-068-A ** ON A/C NOT FOR ALL
A. Fault Isolation for Control Units 4DS and 14DS

If one test indicator on the related control unit does not come on:
  • Do a check of the related fuse.

   (1) If the fuse is not serviceable:
  • Do a check of the aircraft wiring for a short circuit between the related control unit and the inoperative heated floor panel, ASM 252701 or ASM 252702. Use a MULTIMETER - STANDARD.
     (a) If there is a short to ground:
     (b) If there is no short to ground:
       1 If the fault continues:
   (2) If the fuse is serviceable:
  • Do a check of the aircraft wiring between the related control unit and the inoperative heated floor panel, ASM 252701 or ASM 252702. Use a MULTIMETER - STANDARD.
     (a) If there is continuity:
  • Interchange the connector and do the test given in Para. 3.
       1 If the same indicator does not come on:
         a If the fault continues:
     (b) If there is no continuity:
Subtask 25-27-00-810-076-A ** ON A/C NOT FOR ALL
B. Fault Isolation for Control Units 60DS and 66DS

If one test indicator on the related control unit does not come on:
  • Do a check of the related fuse.

   (1) If the fuse is not serviceable:
  • Do a check of the aircraft wiring for a short circuit between the related control unit and the inoperative heated floor panel, ASM 252703. Use a MULTIMETER - STANDARD.
     (a) If there is a short to ground:
  • Repair the aircraft wiring, ASM 252703.
  • Replace the fuse.
     (b) If there is no short to ground:
       1 If the fault continues:
   (2) If the fuse is serviceable:
  • Do a check of the aircraft wiring between the related control unit and the inoperative heated floor panel, ASM 252703. Use a MULTIMETER - STANDARD.
     (a) If there is continuity:
  • Interchange the connectors A and B and do the test given in Para. 3.
       1 If the same indicator does not come on:
         a If the fault continues:
     (b) If there is no continuity:
Subtask 25-27-00-740-063-A ** ON A/C NOT FOR ALL
C. Do the test given in para. 3.A.