No Electrical Power from the aft Master Control Unit (MCU)
TASK 25-21-00-810-869-A
No Electrical Power from the aft Master Control Unit (MCU)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 25-21-00-740-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-21-00-810-243-D ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:27:01 UTC
No Electrical Power from the aft Master Control Unit (MCU)
1. Possible Causes
- MASTER CONTROL UNIT - SEAT POWER SUPPLY [55HP2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 24-00-00-810-803-A | Circuit Breaker Tripped and/or C/B TRIPPED Warning |
| ASM 252100 | |
| AMM 25-21-00-740-001 | BITE Test of the Master Control Unit (MCU) |
| AWM 252132 | |
| AMM 25-21-34-000-001 | Removal of the Master Control Unit (MCU) |
| AMM 25-21-34-400-001 | Installation of the Master Control Unit (MCU) |
Subtask 25-21-00-740-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 25-21-00-810-243-D ** ON A/C NOT FOR ALL
A. If the test confirms the fault, refer to the MCU indication panel:
(1) If the POWER STATE LED is OFF:
(a) Make sure that the PAX SYS switch is in the ON position.
(b) If the fault continues:
(c) Do a check of the circuit breaker 59HP on the panel 2000VU:
1 If it is closed, make sure that the busbar 220XP is energized.
2 If it is open, do a check of the wiring between the circuit breaker panel and the MCU (Ref. TSM TASK 24-00-00-810-803) AWM 252132.
(2) If the GENERAL BITE LED is OFF:
(a) Replace the MASTER CONTROL UNIT - SEAT POWER SUPPLY [55HP2] AMM 25-21-34-000-001 and AMM 25-21-34-400-001.
(3) If the GENERAL BITE and the PORT BITE LEDs are OFF:
(a) Do a check and repair the wiring (Ref. TSM TASK 24-00-00-810-803) ASM 252100.
(4) If the PORT POWER STATUS LEDs are OFF:
(a) Replace the MCU (55HP2) AMM 25-21-34-000-001 and AMM 25-21-34-400-001.
Subtask 25-21-00-710-105-A ** ON A/C NOT FOR ALL (1) If the POWER STATE LED is OFF:
(a) Make sure that the PAX SYS switch is in the ON position.
(b) If the fault continues:
(c) Do a check of the circuit breaker 59HP on the panel 2000VU:
1 If it is closed, make sure that the busbar 220XP is energized.
2 If it is open, do a check of the wiring between the circuit breaker panel and the MCU (Ref. TSM TASK 24-00-00-810-803) AWM 252132.
(2) If the GENERAL BITE LED is OFF:
(a) Replace the MASTER CONTROL UNIT - SEAT POWER SUPPLY [55HP2] AMM 25-21-34-000-001 and AMM 25-21-34-400-001.
(3) If the GENERAL BITE and the PORT BITE LEDs are OFF:
(a) Do a check and repair the wiring (Ref. TSM TASK 24-00-00-810-803) ASM 252100.
(4) If the PORT POWER STATUS LEDs are OFF:
(a) Replace the MCU (55HP2) AMM 25-21-34-000-001 and AMM 25-21-34-400-001.
B. Do the test given in Para. 3.