W DOC AIRBUS | TSM A320F

The ON lamp of the PED switch in the cabin does not come on


TASK 25-21-00-810-801-A
The ON lamp of the PED switch in the cabin does not come on


1. Possible Causes
  • MODULE-CABIN ASSIGNMENT [115RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-861-001
Energize the Cabin Intercommunication Data System (CIDS)
AMM 23-73-19-400-002
Installation of the Cabin Assignment Module
ASM 252100
3. Fault Confirmation
Subtask 25-21-00-710-050-C ** ON A/C NOT FOR ALL
A. No ON lamp installed on the PED switch - LED device controlled by CIDS (Flight Attendant Panel 120RH).
Subtask 25-21-00-710-050-D ** ON A/C NOT FOR ALL
A. Test
   (1) Make sure that the Cabin Intercommunication Data-System (CIDS) is energized AMM 23-73-00-861-001.
   (2) Push the PED POWER switch on the FAP (120RH) to the ON position and make sure that the indicator changes from amber to green.
4. Fault Isolation
Subtask 25-21-00-810-071-E ** ON A/C NOT FOR ALL
A. No ON lamp installed on the PED switch - LED device controlled by CIDS (Flight Attendant Panel 120RH).
Subtask 25-21-00-710-071-C ** ON A/C NOT FOR ALL
B. No ON lamp installed on the PED switch - LED device controlled by CIDS (Flight Attendant Panel 120RH).
Subtask 25-21-00-810-071-F ** ON A/C NOT FOR ALL
C. If the indicator:
  • Stays amber, do step (1)
  • Is OFF, do step (2).
   (1) Do a check and repair the wiring between the MCU and the CIDS-director ASM 252100.
     (a) If the fault continues:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) Do a check for the correct installation of the current MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-400-002.
     (a) If the fault continues:
  • Do the trouble shooting procedure related to the maintenance message.
Subtask 25-21-00-710-071-A ** ON A/C NOT FOR ALL
D. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:27:00 UTC